MB Sample ID: SA151947
Local Sample ID: | F6 |
Subject ID: | SU001735 |
Subject Type: | Yeast |
Subject Species: | Saccharomyces cerevisiae |
Taxonomy ID: | 4932 |
Cell Strain Details: | BY4741 |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU001735 |
Subject Type: | Yeast |
Subject Species: | Saccharomyces cerevisiae |
Taxonomy ID: | 4932 |
Cell Strain Details: | BY4741 |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
F6 | SA151947 | FL017875 | HPLC fraction 6 | Treatment |
Collection:
Collection ID: | CO001728 |
Collection Summary: | Yeast cultures were grown in SC-sulfate media and were harvested at OD600 0.4-0.8 by vacuum filtration then washed with 100mM ammonium acetate - TEA (pH 8.0). Metabolites were extracted by the addition of pre-chilled 10mL 90% methanol, 10mM ammonium acetate - TEA (pH 8.0). Cell debris was removed by centrifugation at 4000g for 10-15 minutes. Extracts were subsequently passed through 3 kDa MWCO filters. Filtrate was diluted 2-fold with water and lyophilized. Lyophilized metabolite extracts were resuspended with water and pH was adjusted to 10 with TEA. The extract was then passed through a mixed-mode anion exchange solid phase extraction cartridge and fractionated by reverse-phase HPLC on a C18 column. One column volume of water plus 0.1% formic acid and eight column volumes of methanol were passed through the column. Fractions that eluted during the aqueous phase were then lyophilized. |
Sample Type: | Yeast cells |
Treatment:
Treatment ID: | TR001748 |
Treatment Summary: | Active fractions were run on a normal-phase HPLC on an amide column and fractions were collected. Fractions 4, 5, and 6 were subjected to metabolomics analyses. |
Sample Preparation:
Sampleprep ID: | SP001741 |
Sampleprep Summary: | Fractions of interest were lyophilized then reconstituted in water plus 0.1% formic acid such that samples reached a final concentration of 20 mg/mL. |
Combined analysis:
Analysis ID | AN002706 | AN002707 | AN002708 | AN002709 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | Normal phase | Normal phase |
Chromatography system | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS |
Column | Thermo Hypersil Gold aQ (150 x 2.1mm,1.9um) | Thermo Hypersil Gold aQ (150 x 2.1mm,1.9um) | PolyLC Polyhydroxyethyl A (200 x 2.1mm,5um) | PolyLC Polyhydroxyethyl A (200 x 2.1mm,5um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | Peak Area | Peak Area | Peak Area | Peak Area |
Chromatography:
Chromatography ID: | CH001997 |
Instrument Name: | Thermo Dionex Ultimate 3000 RS |
Column Name: | Thermo Hypersil Gold aQ (150 x 2.1mm,1.9um) |
Column Temperature: | 30 |
Flow Gradient: | 0-2min 0% B, 2-13min 0-60% B, 13-15min 60-90% B, 15-16min 90-0% B, 16-20min 0% B |
Flow Rate: | 0.2 mL/min |
Solvent A: | 100% water; 0.1% formic acid; 1mM ammonium acetate |
Solvent B: | 20% water/80% acetonitrile; 0.1% formic acid; 1 mM ammonium acetate |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH001998 |
Instrument Name: | Thermo Dionex Ultimate 3000 RS |
Column Name: | PolyLC Polyhydroxyethyl A (200 x 2.1mm,5um) |
Column Temperature: | 30 |
Flow Gradient: | 0-2min 80% B, 2-13min 80-40% B, 13-15min 40-10% B, 15-16min 10-80% B, 16-20min 80% B |
Flow Rate: | 0.2 mL/min |
Solvent A: | 100% water; 0.1% formic acid; 1mM ammonium acetate |
Solvent B: | 20% water/80% acetonitrile; 0.1% formic acid; 1 mM ammonium acetate |
Chromatography Type: | Normal phase |
MS:
MS ID: | MS002503 |
Analysis ID: | AN002706 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | MS1 data was acquired at a resolution of 140,000 over a scan range of 65-850 m/z. Data was analyzed with Thermo Compound Discoverer software. |
Ion Mode: | POSITIVE |
MS ID: | MS002504 |
Analysis ID: | AN002707 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | MS1 data was acquired at a resolution of 140,000 over a scan range of 65-850 m/z. Data was analyzed with Thermo Compound Discoverer software. |
Ion Mode: | NEGATIVE |
MS ID: | MS002505 |
Analysis ID: | AN002708 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | MS1 data was acquired at a resolution of 140,000 over a scan range of 65-850 m/z. Data was analyzed with Thermo Compound Discoverer software. |
Ion Mode: | POSITIVE |
MS ID: | MS002506 |
Analysis ID: | AN002709 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | MS1 data was acquired at a resolution of 140,000 over a scan range of 65-850 m/z. Data was analyzed with Thermo Compound Discoverer software. |
Ion Mode: | NEGATIVE |