MB Sample ID: SA162644

Local Sample ID:treat3
Subject ID:SU001809
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001809
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
treat3SA162644FL019217TreatmentFactor

Collection:

Collection ID:CO001802
Collection Summary:NCI/ADR-RES cells were verified to be of ovarian origin by genotyping. All cancer cell lines were maintained in RPMI 1640 (Sigma R8758) containing glucose (2 mg/ml) and glutamine (0.6 mg/ml) but no pyruvate and was supplemented with 5% Fetal calf serum.
Sample Type:Cultured cells

Treatment:

Treatment ID:TR001822
Treatment Summary:Cells were cultured under normal conditions, detached using trypsin-EDTA (0.05 %), counted, normalized to 0.5 x 106 in each sample, and then cell pellets were snap frozen in liquid nitrogen prior to analysis. To determine the effect of N-MCJ mimetic treatment, equal numbers of NCI/ADR-RES cells were plated and allowed grow for 2 d followed by the addition of vehicle or MITOx30 (25 μM) for 12 h. Cells were then collected and processed as above.

Sample Preparation:

Sampleprep ID:SP001815
Sampleprep Summary:Metabolomics and flux analyses were performed as previously reported 31,61. Briefly, 2 x 106 cells and 20 μl of cell media were extracted in 1 mL and 980 μL of cold lysis and extraction buffer (methanol : acetonitrile : water, 5:3:2), respectively.

Combined analysis:

Analysis ID AN002819 AN002820
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) Phenomenex Kinetex C18 (150 x 2.1mm,2.6um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Relative Abundance Relative Abundance

Chromatography:

Chromatography ID:CH002084
Chromatography Summary:Positive Mode 10 μL of water and methanol soluble fractions were run through a Kinetex C18 1.7 μm, 100 x 2.1 mm (Phenomenex) reversed phase column (Positive ion mode - phase A: water, 0.1 % formic acid; B: acetonitrile, 0.1 % formic acid) via an ultra-high performance chromatographic system (UHPLC - Vanquish, Thermo Fisher). UHPLC was coupled in line with a high-resolution quadrupole Orbitrap instrument run in positive polarity mode (QExactive, Thermo Fisher) at 70,000 resolution (at 200 m/z). Gradients and other technical parameters and the variants employed herein have been extensively described.
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (150 x 2.1mm,2.6um)
Solvent A:100% water; 0.1 % formic acid
Solvent B:100% acetonitrile, 0.1 % formic acid
Chromatography Type:Reversed phase
  
Chromatography ID:CH002085
Chromatography Summary:Negative Mode 10 μL of water and methanol soluble fractions were run through a Kinetex C18 1.7 μm, 100 x 2.1 mm (Phenomenex) reversed phase column (Negative ion mode – phase A: 1 mM NH4Ac 95:5 water : acetonitrile; phase B: 1 mM NH4Ac 95:5 acetonitrile : water) via an ultra-high performance chromatographic system (UHPLC - Vanquish, Thermo Fisher). UHPLC was coupled in line with a high-resolution quadrupole Orbitrap instrument run in negative polarity mode (QExactive, Thermo Fisher) at 70,000 resolution (at 200 m/z). Gradients and other technical parameters and the variants employed herein have been extensively described.
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (150 x 2.1mm,2.6um)
Solvent A:95% water/5% acetonitrile; 1 mM ammonium acetate
Solvent B:95% acetonitrile/5% water; 1 mM ammonium acetate
Chromatography Type:Reversed phase

MS:

MS ID:MS002613
Analysis ID:AN002819
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:UHPLC was coupled in line with a high-resolution quadrupole Orbitrap instrument run in positive polarity mode (QExactive, Thermo Fisher) at 70,000 resolution (at 200 m/z). Gradients and other technical parameters and the variants employed herein have been extensively described.
Ion Mode:POSITIVE
  
MS ID:MS002614
Analysis ID:AN002820
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:UHPLC was coupled in line with a high-resolution quadrupole Orbitrap instrument run in negative polarity mode (QExactive, Thermo Fisher) at 70,000 resolution (at 200 m/z). Gradients and other technical parameters and the variants employed herein have been extensively described.
Ion Mode:NEGATIVE
  logo