Return to study ST001749 main page

MB Sample ID: SA163806

Local Sample ID:UWIM-11181
Subject ID:SU001826
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:55 - 73
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001826
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:55 - 73
Gender:Male and female

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
UWIM-11181SA163806FL019471Enhanced Physical ActivityTreatment
UWIM-11181SA163806FL019471PreTimepoint

Collection:

Collection ID:CO001819
Collection Summary:Fasting blood samples were collected into a 10mL EDTA vacutainer which was gently inverted 10–12 times. Within one hour of collection, EDTA tubes were centrifuged at 3000rpm for 15 minutes at room temperature. Cell-free plasma was aliquoted into cryovials and stored at –80° C and was not thawed until assays were run.
Sample Type:Blood (plasma)
Collection Method:Fasting venipuncture
Storage Conditions:-80℃
Collection Vials:EDTA Vacutainer
Storage Vials:Cryovial

Treatment:

Treatment ID:TR001839
Treatment Summary:Participants were randomized after baseline assessment to either Usual Physical Activity (UPA) or Enhanced Physical Activity (EPA) using 1:1 block randomization accounting for age and sex. UPA group was given educational material about maintaining a healthy and active lifestyle. The EPA group engaged in a supervised, progressive, moderate-to-vigorous intensity aerobic exercise training program three times per week for 50 minutes per session from week seven through 26.

Sample Preparation:

Sampleprep ID:SP001832
Sampleprep Summary:Samples were prepared using the MicroLab STAR system from Hamilton Company. Recovery standards were added prior to the first step in the extraction process. To remove protein, dissociate small molecules bound to protein or trapped in the precipitated protein matrix, and to recover chemically diverse metabolites, proteins were precipitated with methanol under vigorous shaking for 2 min (Glen Mills GenoGrinder 2000) followed by centrifugation. The resulting extract was divided into five fractions: two for analysis by two separate reverse phase (RP)/UPLC-MS/MS methods with positive ion mode electrospray ionization (ESI), one for analysis by RP/UPLC-MS/MS with negative ion mode ESI, one for analysis by HILIC/UPLC-MS/MS with negative ion mode ESI, and one sample was reserved for backup. Samples were placed briefly on a TurboVap (Zymark) to remove the organic solvent. The sample extracts were stored overnight under nitrogen before preparation for analysis.

Combined analysis:

Analysis ID AN002848 AN002849 AN002850 AN002851
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units Raw area counts Raw area counts Raw area counts Raw area counts

Chromatography:

Chromatography ID:CH002109
Chromatography Summary:Two fractions were analyzed using positive ion mode electrospray ionization optimized for hydrophilic compounds. One fraction was analyzed using negative ion mode electrospray ionization.
Instrument Name:Waters Acquity
Column Name:Waters Acquity BEH C18 (100 x 2mm,1.7um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH002110
Chromatography Summary:One fraction was analyzed via negative ion mode electrospray ionization from Hydrophilic-Interaction Chromatography (HILIC) column.
Instrument Name:Waters Acquity
Column Name:Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
Chromatography Type:HILIC

MS:

MS ID:MS002641
Analysis ID:AN002848
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:POSITIVE
  
MS ID:MS002642
Analysis ID:AN002849
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:POSITIVE
  
MS ID:MS002643
Analysis ID:AN002850
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:NEGATIVE
  
MS ID:MS002644
Analysis ID:AN002851
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:NEGATIVE
  logo