Return to study ST001828 main page
MB Sample ID: SA169825
Local Sample ID: | Sample2207 |
Subject ID: | SU001905 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU001905 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
Sample2207 | SA169825 | FL020230 | NO | PRETERM BIRTH |
Collection:
Collection ID: | CO001898 |
Collection Summary: | Standard blood plasma collection protocol |
Sample Type: | Blood (plasma) |
Storage Conditions: | -80℃ |
Treatment:
Treatment ID: | TR001918 |
Treatment Summary: | This is an observational study, no specific treatment was applied. |
Sample Preparation:
Sampleprep ID: | SP001911 |
Sampleprep Summary: | MRC2 untargeted metabolomics sample preparation protocol |
Sampleprep Protocol Filename: | Untargeted_metabolomics_analysis.DOC |
Combined analysis:
Analysis ID | AN002964 | AN002965 | AN002966 | AN002967 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | Reversed phase | Reversed phase |
Chromatography system | Agilent 1290 Infinity II | Agilent 1290 Infinity II | Agilent 1290 Infinity II | Agilent 1290 Infinity II |
Column | Waters Acquity BEH C18 (100 x 2mm,1.7um) | Waters Acquity BEH C18 (100 x 2mm,1.7um) | Waters Acquity BEH C18 (100 x 2mm,1.7um) | Waters Acquity BEH C18 (100 x 2mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | QTOF | QTOF | QTOF | QTOF |
MS instrument name | Agilent 6445 Q-TOF | Agilent 6445 Q-TOF | Agilent 6445 Q-TOF | Agilent 6445 Q-TOF |
Ion Mode | POSITIVE | POSITIVE | NEGATIVE | NEGATIVE |
Units | Peak area | Peak area | Peak area | Peak area |
Chromatography:
Chromatography ID: | CH002197 |
Chromatography Summary: | Positive mode RP |
Instrument Name: | Agilent 1290 Infinity II |
Column Name: | Waters Acquity BEH C18 (100 x 2mm,1.7um) |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH002198 |
Chromatography Summary: | Negative mode RP |
Instrument Name: | Agilent 1290 Infinity II |
Column Name: | Waters Acquity BEH C18 (100 x 2mm,1.7um) |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS002754 |
Analysis ID: | AN002964 |
Instrument Name: | Agilent 6445 Q-TOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Positive mode untargeted analysis |
Ion Mode: | POSITIVE |
MS ID: | MS002755 |
Analysis ID: | AN002965 |
Instrument Name: | Agilent 6445 Q-TOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Positive mode identified compounds |
Ion Mode: | POSITIVE |
MS ID: | MS002756 |
Analysis ID: | AN002966 |
Instrument Name: | Agilent 6445 Q-TOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Negative mode untargeted analysis |
Ion Mode: | NEGATIVE |
MS ID: | MS002757 |
Analysis ID: | AN002967 |
Instrument Name: | Agilent 6445 Q-TOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Negative mode identified compounds |
Ion Mode: | NEGATIVE |