Return to study ST002028 main page

MB Sample ID: SA190720

Local Sample ID:RS-01683157
Subject ID:SU002110
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002110
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
RS-01683157SA190720FL023453Pre-interventionTreatment

Collection:

Collection ID:CO002103
Collection Summary:: Samples were taken before and after 6 weeks of flaxseed dietary intervention. Serum and fecal metabolomics were performed to characterize the metabolomic profiles of serum and stool metabolites pre- and post-intervention.
Sample Type:Feces

Treatment:

Treatment ID:TR002122
Treatment Summary:: Samples were taken before and after 6 weeks of flaxseed dietary intervention. Serum and fecal metabolomics were performed to characterize the metabolomic profiles of serum and stool metabolites pre- and post-intervention.

Sample Preparation:

Sampleprep ID:SP002116
Sampleprep Summary:Extraction is carried out using a bi-phasic solvent system of cold methanol, methyl tert-butyl ether (MTBE), and water. In more detail, cold methanol (225 µL is added to a 5mg tissue sample aliquot, which is placed into a 1.5 mL Eppendorf tube. Then, 750 µL of cold MTBE is added, followed by vortexing for 10 s. and shaking for 6 min. at 4ºC. Phase separation is induced by adding 188 µL of mass spec-grade water. After vortexing for 20 s. the sample is centrifuged at 14,000 rpm for 2 min. The upper organic phase is collected in two 300 µL aliquots for lipid analysis polar layer is collected in two 125 µL aliquots for HILIC analysis. One is stored at -20ºC as a backup and the other is evaporated to dryness in a SpeedVac. Dried extracts are resuspended in acetonitrile.

Combined analysis:

Analysis ID AN003298
Analysis type MS
Chromatography type HILIC
Chromatography system Vanquish
Column Waters Acquity UPLC BEH amide,(150 x 2.1mm,1.7um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE
Units normalized peak height

Chromatography:

Chromatography ID:CH002437
Instrument Name:Vanquish
Column Name:Waters Acquity UPLC BEH amide,(150 x 2.1mm,1.7um)
Chromatography Type:HILIC

MS:

MS ID:MS003068
Analysis ID:AN003298
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A Thermo Q-Exactive HF Orbitrap MS instrument was operated in positive and negative ESI mdoes respectively with the following parameters: mass range 60−900 m/z; spray voltage 3.6kV (ESI+) and −3kV (ESI−), sheath gas (nitrogen) flow rate 60 units; auxiliary gas (nitrogen) flow rate 25 units, capillary temperature 320 ◦C, full scan MS1 mass resolving power 60,000, data-dependent MSMS (dd-MSMS) 4 scans per cycle, normalized collision energy at 20%, 30%, and 40%, dd-MSMS mass resolving power 15,000. Thermo Xcalibur 4.0.27.19 was used for data acquisition and analysis. Instruments was tuned and calibrated by manufacturer’s recommendations.
Ion Mode:POSITIVE
  logo