Return to study ST002108 main page

MB Sample ID: SA202357

Local Sample ID:DMSO_iRBC_p_1
Subject ID:SU002193
Subject Type:Cultured cells
Subject Species:Plasmodium falciparum
Taxonomy ID:5833

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002193
Subject Type:Cultured cells
Subject Species:Plasmodium falciparum
Taxonomy ID:5833

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
DMSO_iRBC_p_1SA202357FL024604iRBCcell_type
DMSO_iRBC_p_1SA202357FL024604DMSOtreatment

Collection:

Collection ID:CO002186
Collection Summary:Pf3D7 cultures underwent double sorbitol synchronization 14 h apart, followed by further incubation for 28-42 h to achieve the desired trophozoite stage (28 hpi) at 6% parasitaemia and 2% hematocrit. Infected RBCs (2x108) were treated with 10x the EC50 of compound 3 for 1 h, after which metabolites were extracted. During the drug incubation period parasites were at 37°C under a gas atmosphere of 94% N2, 5% CO2 and 1% O2. All samples were centrifuged at 650 g for 3 min, the supernatant was removed, and the pellet washed in 500 µL of ice-cold PBS. Samples were again centrifuged at 650 g for 3 min and pellets were resuspended in 150 µL of ice-cold extraction buffer (100% methanol) and quickly resuspended. The samples were then incubated on a vortex mixer for 1 h at 4°C before being centrifuged at 17,000 g for 10 min; from this 100 µL of supernatant was collected and stored at -80°C until analysis. For each sample, another 10 µL was collected and pooled, to serve as a quality control (QC) sample.
Sample Type:Blood (whole)

Treatment:

Treatment ID:TR002205
Treatment Summary:Pf3D7 cultures underwent double sorbitol synchronization 14 h apart, followed by further incubation for 28-42 h to achieve the desired trophozoite stage (28 hpi) at 6% parasitaemia and 2% hematocrit. Infected RBCs (2x108) were treated with 10x the EC50 of compound 3 for 1 h, after which metabolites were extracted. During the drug incubation period parasites were at 37°C under a gas atmosphere of 94% N2, 5% CO2 and 1% O2. All samples were centrifuged at 650 g for 3 min, the supernatant was removed, and the pellet washed in 500 µL of ice-cold PBS. Samples were again centrifuged at 650 g for 3 min and pellets were resuspended in 150 µL of ice-cold extraction buffer (100% methanol) and quickly resuspended. The samples were then incubated on a vortex mixer for 1 h at 4°C before being centrifuged at 17,000 g for 10 min; from this 100 µL of supernatant was collected and stored at -80°C until analysis. For each sample, another 10 µL was collected and pooled, to serve as a quality control (QC) sample.

Sample Preparation:

Sampleprep ID:SP002199
Sampleprep Summary:Pf3D7 cultures underwent double sorbitol synchronization 14 h apart, followed by further incubation for 28-42 h to achieve the desired trophozoite stage (28 hpi) at 6% parasitaemia and 2% hematocrit. Infected RBCs (2x108) were treated with 10x the EC50 of compound 3 for 1 h, after which metabolites were extracted. During the drug incubation period parasites were at 37°C under a gas atmosphere of 94% N2, 5% CO2 and 1% O2. All samples were centrifuged at 650 g for 3 min, the supernatant was removed, and the pellet washed in 500 µL of ice-cold PBS. Samples were again centrifuged at 650 g for 3 min and pellets were resuspended in 150 µL of ice-cold extraction buffer (100% methanol) and quickly resuspended. The samples were then incubated on a vortex mixer for 1 h at 4°C before being centrifuged at 17,000 g for 10 min; from this 100 µL of supernatant was collected and stored at -80°C until analysis. For each sample, another 10 µL was collected and pooled, to serve as a quality control (QC) sample.

Combined analysis:

Analysis ID AN003448 AN003449
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS
Column ZIC-pHILIC (150 x 4.6mm,5um) equipped with a guard (SeQuant,Merck) ZIC-pHILIC (150 x 4.6mm,5um) equipped with a guard (SeQuant,Merck)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units relative intensity relative intensity

Chromatography:

Chromatography ID:CH002547
Instrument Name:Thermo Dionex Ultimate 3000 RS
Column Name:ZIC-pHILIC (150 x 4.6mm,5um) equipped with a guard (SeQuant,Merck)
Chromatography Type:HILIC

MS:

MS ID:MS003211
Analysis ID:AN003448
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolite detection was performed using a high-resolution Q Exactive MS (ThermoFisher) in both positive and negative ionisation modes. The PBQC sample was run periodically throughout each LC-MS batch to monitor signal reproducibility and support downstream metabolite identification. Extraction solvent blank samples were also analysed to identify possible contaminating chemical species. To aid in metabolite identification, approximately 250 authentic metabolite standards were analysed prior to each LC-MS batch and their peaks and retention time manually checked using the ToxID software (ThermoFisher). Metabolomics data were analysed using the IDEOM workflow (Creek et al. 2012). Briefly, the IDEOM processing pipeline uses msconvert for conversion of raw files to mzXML files and split polarity, XCMS to extract raw peak intensities and mzMatch to align samples, filter noise, fill missing peaks and annotate related peaks. Manual assessment of spiked internal standards, total ion chromatograms and median peak heights ensured signal reproducibility and allowed exclusion of outlier samples. LC MS peak heights representing metabolite abundances were normalised by median peak height. High confidence metabolite identification (MSI level 1) was made by matching accurate mass and retention time to authentic metabolite standards. Putative identifications (MSI level 2) for metabolites lacking standards were based on exact mass and predicted retention times.
Ion Mode:POSITIVE
  
MS ID:MS003212
Analysis ID:AN003449
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolite detection was performed using a high-resolution Q Exactive MS (ThermoFisher) in both positive and negative ionisation modes. The PBQC sample was run periodically throughout each LC-MS batch to monitor signal reproducibility and support downstream metabolite identification. Extraction solvent blank samples were also analysed to identify possible contaminating chemical species. To aid in metabolite identification, approximately 250 authentic metabolite standards were analysed prior to each LC-MS batch and their peaks and retention time manually checked using the ToxID software (ThermoFisher). Metabolomics data were analysed using the IDEOM workflow (Creek et al. 2012). Briefly, the IDEOM processing pipeline uses msconvert for conversion of raw files to mzXML files and split polarity, XCMS to extract raw peak intensities and mzMatch to align samples, filter noise, fill missing peaks and annotate related peaks. Manual assessment of spiked internal standards, total ion chromatograms and median peak heights ensured signal reproducibility and allowed exclusion of outlier samples. LC MS peak heights representing metabolite abundances were normalised by median peak height. High confidence metabolite identification (MSI level 1) was made by matching accurate mass and retention time to authentic metabolite standards. Putative identifications (MSI level 2) for metabolites lacking standards were based on exact mass and predicted retention times.
Ion Mode:NEGATIVE