Return to study ST002205 main page

MB Sample ID: SA211376

Local Sample ID:LV18_07
Subject ID:SU002291
Subject Type:Cultured cells
Subject Species:Mus musculus
Taxonomy ID:10090

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002291
Subject Type:Cultured cells
Subject Species:Mus musculus
Taxonomy ID:10090

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
LV18_07SA211376FL025777Fh1 fl/flGenotype
LV18_07SA211376FL025777sg1HiraTreatment

Collection:

Collection ID:CO002284
Collection Summary:Cells were seeded in 6-well plates and collected the following day at 70% confluency. Cells were washed at room temperature with PBS twice and then kept on cold bath with dry ice and methanol. Metabolite extraction solution (50% methanol, 30% acetonitrile, 20% ultrapure water, 5 µM final concentration valine-d8) was added to each well following the proportion of 0.5 ml of extraction solution per million cells. The extracts were scraped and mixed at 4°C for 15 min. After final centrifugation at max speed for 15 min at 4°C, the supernatants were transferred into LC-MS vials.
Sample Type:kidney epithelial cells

Treatment:

Treatment ID:TR002303
Treatment Summary:Fh1-deficient cells expressing Cas9 were transduced with gRNA against Hira (g1Hira). No further treatments were carried out. Cells were cultured using high glucose (4.5 g/L) DMEM (Gibco-41966-029) supplemented with 10% heat inactivated fetal bovine serum (FBS).

Sample Preparation:

Sampleprep ID:SP002297
Sampleprep Summary:Cells were seeded in 6-well plates and collected the following day at 70% confluency. Cells were washed at room temperature with PBS twice and then kept on cold bath with dry ice and methanol. Metabolite extraction solution (50% methanol, 30% acetonitrile, 20% ultrapure water, 5 µM final concentration valine-d8) was added to each well following the proportion of 0.5 ml of extraction solution per million cells. The extracts were scraped and mixed at 4°C for 15 min. After final centrifugation at max speed for 15 min at 4°C, the supernatants were transferred into LC-MS vials.

Combined analysis:

Analysis ID AN003608
Analysis type MS
Chromatography type HILIC
Chromatography system Dionex Ultimate 3000 UHPLC
Column SeQuant ZIC-pHILIC
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode UNSPECIFIED
Units peak area

Chromatography:

Chromatography ID:CH002667
Chromatography Summary:Chromatographic separation of polar metabolites was achieved using a Millipore Sequant ZIC-pHILIC analytical column (5 µm, 2.1 × 150 mm) equipped with a 2.1 × 20 mm guard column (both 5 mm particle size) with a binary solvent system. Solvent A was 20 mM ammonium carbonate, 0.05% ammonium hydroxide; Solvent B was acetonitrile. The column oven and autosampler tray were held at 40 °C and 4 °C, respectively. The chromatographic gradient was run at a flow rate of 0.200 mL/min as follows: 0–2 min: 80% B; 2-17 min: linear gradient from 80% B to 20% B; 17-17.1 min: linear gradient from 20% B to 80% B; 17.1-22.5 min: hold at 80% B. Samples were randomized and analysed with LC–MS in a blinded manner with an injection volume was 5 µl. Pooled samples were generated from an equal mixture of all individual samples and analysed interspersed at regular intervals within sample sequence as a quality control.
Instrument Name:Dionex Ultimate 3000 UHPLC
Column Name:SeQuant ZIC-pHILIC
Column Temperature:40
Flow Gradient:0-2 min: 80% B; 2-17 min: linear gradient from 80% B to 20% B; 17-17.1 min: linear gradient from 20% B to 80% B; 17.1-23 min: hold at 80% B.
Flow Rate:0.200 mL/min
Solvent A:100% water; 20 mM ammonium carbonate; 0.05% ammonium hydroxide
Solvent B:100% acetonitrile
Chromatography Type:HILIC

MS:

MS ID:MS003362
Analysis ID:AN003608
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolites were measured with a Thermo Scientific Q Exactive Hybrid Quadrupole-Orbitrap Mass spectrometer (HRMS) coupled to a Dionex Ultimate 3000 UHPLC. The mass spectrometer was operated in full-scan, polarity-switching mode, with the spray voltage set to +4.5 kV/-3.5 kV, the heated capillary held at 320 °C, and the auxiliary gas heater held at 280 °C. The sheath gas flow was set to 55 units, the auxiliary gas flow was set to 15 units, and the sweep gas flow was set to 0 unit. HRMS data acquisition was performed in a range of m/z = 70–900, with the resolution set at 70,000, the AGC target at 1 × 106, and the maximum injection time (Max IT) at 120 ms. Metabolite identities were confirmed using two parameters: (1) precursor ion m/z was matched within 5 ppm of theoretical mass predicted by the chemical formula; (2) the retention time of metabolites was within 5% of the retention time of a purified standard run with the same chromatographic method. Chromatogram review and peak area integration were performed using the Thermo Fisher software Tracefinder 5.0 and the peak area for each detected metabolite was normalized against the total ion count (TIC) of that sample to correct any variations introduced from sample handling through instrument analysis. The normalized areas were used as variables for further statistical data analysis.
Ion Mode:UNSPECIFIED
  logo