Return to study ST002376 main page
MB Sample ID: SA237381
Local Sample ID: | WT3 |
Subject ID: | SU002465 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Genotype Strain: | C57BL/6N |
Age Or Age Range: | 6-weeks old |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU002465 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Genotype Strain: | C57BL/6N |
Age Or Age Range: | 6-weeks old |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
WT3 | SA237381 | FL029403 | Wild-type | Genotype |
Collection:
Collection ID: | CO002458 |
Collection Summary: | Mice were deeply anesthetized and perfused intracardially with saline containing 1 mM MOPS (pH 7.4). Liver was rapidly removed, frozen on liquid nitrogen and stored at –80°C until further processing. |
Sample Type: | Liver |
Storage Conditions: | -80℃ |
Treatment:
Treatment ID: | TR002477 |
Treatment Summary: | No treatment in this study. |
Sample Preparation:
Sampleprep ID: | SP002471 |
Sampleprep Summary: | Tissues with internal standards were homogenized with ice-cold acetonitrile:water (50:50) and centrifuged at 2,300 × g for 5 min at 4 °C. The supernatant was filtered through a 5-kDa cut-off filter (Ultrafree-MC-PLHCC, Human Metabolome Technologies) at 9,100 × g for 2 h at 4 °C, dried in a centrifugal evaporator at 1,500 rpm at 1,000 Pa, and resuspended in 50 μl of ultrapure water before metabolome analysis. |
Combined analysis:
Analysis ID | AN003871 | AN003872 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | CE | CE |
Chromatography system | Agilent 7100 CE | Agilent 7100 CE |
Column | Fused silica capillary i.d. 50 μm × 80 cm | Fused silica capillary i.d. 50 μm × 80 cm |
MS Type | ESI | ESI |
MS instrument type | Other | Other |
MS instrument name | Agilent CE-TOFMS | Agilent CE-TOFMS |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak area | Peak area |
Chromatography:
Chromatography ID: | CH002869 |
Instrument Name: | Agilent 7100 CE |
Column Name: | Fused silica capillary i.d. 50 μm × 80 cm |
Chromatography Type: | CE |
MS:
MS ID: | MS003612 |
Analysis ID: | AN003871 |
Instrument Name: | Agilent CE-TOFMS |
Instrument Type: | Other |
MS Type: | ESI |
MS Comments: | The spectrometer was scanned from m/z 50 to 1,000. Peaks were extracted using automatic integration software MasterHands (ver.2.16.0.15 Keio University). Signal peaks corresponding to isotopomers, adduct ions, and other product ions of known metabolites were excluded, and remaining peaks were annotated with putative metabolites from the HMT metabolite database based on their migration time and m/z values. Peak areas were normalized to internal standards and sample amounts. |
Ion Mode: | POSITIVE |
MS ID: | MS003613 |
Analysis ID: | AN003872 |
Instrument Name: | Agilent CE-TOFMS |
Instrument Type: | Other |
MS Type: | ESI |
MS Comments: | The spectrometer was scanned from m/z 50 to 1,000. Peaks were extracted using automatic integration software MasterHands (ver.2.16.0.15 Keio University). Signal peaks corresponding to isotopomers, adduct ions, and other product ions of known metabolites were excluded, and remaining peaks were annotated with putative metabolites from the HMT metabolite database based on their migration time and m/z values. Peak areas were normalized to internal standards and sample amounts. |
Ion Mode: | NEGATIVE |