Return to study ST002475 main page

MB Sample ID: SA247819

Local Sample ID:PHP7
Subject ID:SU002565
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002565
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
PHP7SA247819FL031167Controltreatment

Collection:

Collection ID:CO002558
Collection Summary:The first pooped fecal sample in a day were collected during 3 days after the indicated time points and stored at -80 oC immediately for further research
Sample Type:Feces

Treatment:

Treatment ID:TR002577
Treatment Summary:Out of those 60 students with anxiety and depression facing UNGEE, 30 were selected randomly as the PB group to receive the probiotic product; another 30 received placebo product were regarded as the P group. The 30 un-anxious students were assigned as the healthy control group (HP group).

Sample Preparation:

Sampleprep ID:SP002571
Sampleprep Summary:Stool weighing 100 mg was added with 400 ml extract of methanol-acetonitrile-water (2:2:1, vol/vol/vol), vortexed and centrifuged at 14,000 g for 20min, and the supernatant was collected for further measurement.

Combined analysis:

Analysis ID AN004042 AN004043
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Agilent 1290 Infinity Agilent 1290 Infinity
Column Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.7um) Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Triple TOF Triple quadrupole
MS instrument name ABI Sciex 6600 TripleTOF ABI Sciex 6600 TripleTOF
Ion Mode POSITIVE NEGATIVE
Units Original peak intensity values Original peak intensity values

Chromatography:

Chromatography ID:CH002990
Instrument Name:Agilent 1290 Infinity
Column Name:Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.7um)
Column Temperature:25
Flow Gradient:The gradient elution program was as follows: 0 --- 0.5 min, 95% B; 0.5 --- 7 min, B varied linearly from 95% to 65 %; 7 --- 8 min, B varied linearly from 65% to 40%; 8---9 min, B was maintained at 40%; 9---9.1 min, B varied linearly from 40% to 95%; 9.1--12 min, B maintained at 95%.
Flow Rate:0.5 mL/min
Solvent A:100% water; 25 mM ammonium acetate; 25 mM ammonia
Solvent B:100% acetonitrile
Chromatography Type:HILIC

MS:

MS ID:MS003789
Analysis ID:AN004042
Instrument Name:ABI Sciex 6600 TripleTOF
Instrument Type:Triple TOF
MS Type:ESI
MS Comments:Ion Source Gas1(Gas1):60,Ion Source Gas2(Gas2):60,Curtain gas (CUR):30,source temperature:600℃,IonSapary Voltage Floating (ISVF) The raw data in Wiff format was converted to .mzXML format by ProteoWizard and then converted to .mzXML format using XCMS software.
Ion Mode:POSITIVE
  
MS ID:MS003790
Analysis ID:AN004043
Instrument Name:ABI Sciex 6600 TripleTOF
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Ion Source Gas1(Gas1):60,Ion Source Gas2(Gas2):60,Curtain gas (CUR):30,source temperature:600℃,IonSapary Voltage Floating (ISVF) The raw data in Wiff format was converted to .mzXML format by ProteoWizard and then converted to .mzXML format using XCMS software.
Ion Mode:NEGATIVE