Return to study ST000899 main page

MB Sample ID: SA052871

Local Sample ID:197
Subject ID:SU000936
Subject Type:Human serum
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001462 AN001463 AN001464 AN001465
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters Acquity BEH C18 (100 x 2.1mm,1.7um) Waters Acquity BEH C18 (100 x 2.1mm,1.7um) Waters Acquity BEH C18 (100 x 2.1mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units raw area counts raw area counts raw area counts raw area counts

Chromatography:

Chromatography ID:CH001028
Chromatography Summary:One aliquot was analyzed using acidic positive ion conditions, chromatographically optimized for more hydrophilic compounds. In this method, the extract was gradient-eluted from a C18 column (Waters UPLC BEH C18-2.1x100 mm, 1.7 µm) using water and methanol, containing 0.05% perfluoropentanoic acid (PFPA) and 0.1% formic acid (FA). A 2nd aliquot was also analyzed using acidic positive ion conditions, however it was chromatographically optimized for more hydrophobic compounds. In this method, the extract was gradient eluted from the same C18 column using methanol, acetonitrile, water, 0.05% PFPA, and 0.01% FA and was operated at an overall higher organic content. A 3rd aliquot was analyzed using basic negative ion optimized conditions using a separate dedicated C18 column. The basic extracts were gradient eluted from the column using methanol and water, however with 6.5mM ammonium bicarbonate at pH 8.
Instrument Name:Waters Acquity
Column Name:Waters Acquity BEH C18 (100 x 2.1mm,1.7um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH001029
Chromatography Summary:The 4th aliquot was analyzed via negative ionization following elution from a HILIC column (Waters UPLC BEH Amide 2.1x150 mm, 1.7 µm) using a gradient consisting of water and acetonitrile with 10mM ammonium formate, pH 10.8.
Instrument Name:Waters Acquity
Column Name:Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
Solvent A:100% water; 10 mM ammonium formate, pH 10.8
Solvent B:100% acetonitrile; 10 mM ammonium formate, pH 10.8
Chromatography Type:HILIC
  logo