Return to study ST001429 main page
MB Sample ID: SA120700
Local Sample ID: | WT-2 |
Subject ID: | SU001503 |
Subject Type: | Cultured cells |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Genotype Strain: | Burkitt lymphoma cell line, wild type and two mutants, 4A and VP16 |
Gender: | Not applicable |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002389 | AN002390 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | HILIC |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Thermo Accucore C18 (100 x 2.1mm,2.6um) | EMD Millipore ZIC-HILIC (100 x 2.1mm,3.5um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap |
Ion Mode | POSITIVE | POSITIVE |
Units | peak area | peak area |
Chromatography:
Chromatography ID: | CH001756 |
Chromatography Summary: | RPLC analysis metabolite extracts (10 μl injection volume) were separated on a Hypersil Gold, 1.9 μm, 2.1mm x 100 mm column (Thermo Fisher) held at 40°C. Liquid chromatography was performed at a 250 μl/min using solvent A (0.1% formic acid in H2O) and solvent B (0.1% formic acid in acetonitrile) with the following gradient: 5% B for 1 minute, 5-50% B over 9 minutes, 50-70% B over 5 minutes, 70-95% B over 5 minutes, 95% B held 2 minutes, and 95-5% B over 3 minutes, 5% B held 5 minutes (gradient length: 30 minutes). |
Methods Filename: | Global untargeted method_MYC_Project |
Instrument Name: | Thermo Vanquish |
Column Name: | Thermo Accucore C18 (100 x 2.1mm,2.6um) |
Column Temperature: | 40 |
Flow Rate: | 0.25 mL/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile, 0.1% formic acid |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH001757 |
Chromatography Summary: | For HILIC analysis metabolite extracts (10 μl injection volume) were separated on a SeQuant ZIC-HILIC 3.5-μm, 2.1 mm × 100 mm column (Millipore Corporation, Darmstadt, Germany) held at 40°C. Liquid chromatography was performed at a 200 μl min−1 using solvent A (5 mM Ammonium formate in 90% H2O, 10% acetonitrile) and solvent B (5 mM Ammonium formate in 90% acetonitrile, 10% H2O) with the following gradient: 95% B for 2 min, 95-40% B over 16 min, 40% B held 2 min, and 40-95% B over 15 min, 95% B held 10 min (gradient length 45 min). |
Methods Filename: | Global untargeted method_MYC_Project |
Instrument Name: | Thermo Vanquish |
Column Name: | EMD Millipore ZIC-HILIC (100 x 2.1mm,3.5um) |
Column Temperature: | 40 |
Flow Rate: | 0.2 mL/min |
Solvent A: | 90% water/10% acetonitrile; 5 mM ammonium formate |
Solvent B: | 90% acetonitrile/10% water; 5 mM ammonium formate |
Chromatography Type: | HILIC |