Return to study ST001683 main page

MB Sample ID: SA155288

Local Sample ID:s1133
Subject ID:SU001760
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Genotype Strain:Swiss Webster
Age Or Age Range:10-14 weeks
Gender:Male

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002747 AN002748 AN002749
Analysis type MS MS MS
Chromatography type Reversed phase Reversed phase HILIC
Chromatography system Agilent qTOF 6545 Agilent qTOF 6545 Agilent qTOF 6545
Column Waters Acquity BEH (100 x 2.1mm,1.7um) Waters Acquity BEH (100 x 2.1mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI
MS instrument type QTOF QTOF QTOF
MS instrument name Agilent qTOF 6545 Agilent qTOF 6545 Agilent qTOF 6545
Ion Mode POSITIVE NEGATIVE POSITIVE
Units Raw ion count (peak area) Raw ion count (peak area) Raw ion count (peak area)

Chromatography:

Chromatography ID:CH002029
Chromatography Summary:Published C18 reveres phase methods were implemented with minor modifications. The C18 positive method (ESI+) used mobile phase solvents (LC-MS grade) consisting of 0.1% formic acid (Fisher) in water (A) and 0.1% formic acid in methanol (B). The gradient profile was from 0.5% B to 70% B in 4 minutes, from 70% B to 98% B in 0.5 minutes, and holding at 98% B for 0.9 minute before returning to 0.5% B in 0.2 minutes. The flow rate was 350 µL per minute. The sample injection volume was 5 µL. LC separations were made at 40oC on separate columns fitted with a Vanguard pre-column of the same composition: Waters Acquity BEH 1.7 µm particle size, 2.1 mm id x 100 mm length (C18). Data were collected at a mass range of 70-1000 m/z at an acquisition rate of 2 spectra per second. Specific ion source parameters included Fragmentor (140V), Gas Temp (250oC), Sheath Gas Temp (200oC), and VCap (4000V).
Instrument Name:Agilent qTOF 6545
Column Name:Waters Acquity BEH (100 x 2.1mm,1.7um)
Column Temperature:40
Flow Gradient:0.5% B to 70% B in 4 minutes, from 70% B to 98% B in 0.5 minutes, and holding at 98% B for 0.9 minute before returning to 0.5% B in 0.2 minutes.
Flow Rate:350 µL/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% methanol; 0.1% formic acid
Chromatography Type:Reversed phase
  
Chromatography ID:CH002030
Chromatography Summary:Published C18 reverse phase methods were implemented with minor modifications. The C18 negative method (ESI-) used mobile phase solvents (LC-MS grade) consisting of 6.5 mM ammonium bicarbonate (Sigma) in water at pH 8 (A) and 6.5 mM ammonium bicarbonate in 95:5 v/v methanol:water (B). The gradient profile was from 0.5% B to 70% B in 4 minutes, from 70% B to 98% B in 0.5 minutes, and holding at 98% B for 0.9 minute before returning to 0.5% B in 0.2 minutes. The flow rate was 350 µL per minute. The sample injection volume was 5 µL. LC separations were made at 40oC on separate columns fitted with a Vanguard pre-column of the same composition: Waters Acquity BEH 1.7 µm particle size, 2.1 mm id x 100 mm length. Data were collected at a mass range of 70-1000 m/z at an acquisition rate of 2 spectra per second. Specific ion source parameters included Fragmentor (140V), Gas Temp (250oC), Sheath Gas Temp (200oC), and VCap (4000V).
Instrument Name:Agilent qTOF 6545
Column Name:Waters Acquity BEH (100 x 2.1mm,1.7um)
Column Temperature:40
Flow Gradient:0.5% B to 70% B in 4 minutes, from 70% B to 98% B in 0.5 minutes, and holding at 98% B for 0.9 minute before returning to 0.5% B in 0.2 minutes.
Flow Rate:350 µL/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% methanol; 0.1% formic acid
Chromatography Type:Reversed phase
  
Chromatography ID:CH002031
Chromatography Summary:Published HILIC method was implemented with minor modifications. The HILIC (Hydrophilic Interaction Liquid Chromatography) positive method (ESI+) used mobile phase solvents (LC-MS grade) consisting of 0.125% formic acid and 10 mM ammonium formate (Sigma) in water at pH 3 (A) and 0.125% formic acid in 10 mM ammonium formate in 95:5 v/v acetonitrile:water (B). The gradient profile was held at 100% B for 2 minutes, from 100% B to 70% B in 5 minutes, holding at 70% B for 0.7 minute, from 70% B to 40% B for 1.3 minutes, holding at 40% B for 0.5 minutes, from 40% B to 30% B for 0.75 minutes, before returning to 100% B for 2.5 minutes and holding at 100% B for 4 minutes. The flow rate was 400 µL per minute. The sample injection volume was 3 µL. LC separations were made at 40oC on separate columns fitted with a Vanguard pre-column of the same composition dedicated to each analytical method: Waters Acquity BEH Amide 1.7 µm particle size, 2.1 mm id x 150 mm length. Data were collected at a mass range of 70-1000 m/z at an acquisition rate of 2 spectra per second. Specific ion source parameters included Fragmentor (140V), Gas Temp (250oC), Sheath Gas Temp (200oC), and VCap (4000V).
Instrument Name:Agilent qTOF 6545
Column Name:Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
Column Temperature:40
Flow Gradient:The gradient profile was held at 100% B for 2 minutes, from 100% B to 70% B in 5 minutes, holding at 70% B for 0.7 minute, from 70% B to 40% B for 1.3 minutes, holding at 40% B for 0.5 minutes, from 40% B to 30% B for 0.75 minutes, before returning to 100% B for 2.5 minutes and holding at 100% B for 4 minutes.
Flow Rate:400 µL/min
Solvent A:100% water; 0.125% formic acid; 10 mM ammonium formate, pH 3
Solvent B:95% acetonitrile/5% water; 0.125% formic acid; 10 mM ammonium formate
Chromatography Type:HILIC
  logo