Return to study ST001692 main page

MB Sample ID: SA156794

Local Sample ID:C-23MQ1-BR-00
Subject ID:SU001769
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Gender:Female

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002762 AN002763
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Higgins Analytical Targa C18 (50 x 2.1mm,5um) Higgins Analytical Targa C18 (50 x 2.1mm,5um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q-Exactive HFX Thermo Q-Exactive HFX
Ion Mode POSITIVE NEGATIVE
Units Peak intensity Peak intensity

Chromatography:

Chromatography ID:CH002042
Chromatography Summary:Sample extracts were analyzed using an ultra-high performance liquid chromatography (UHPLC) equipped with dual pumps for both C18-pos and C18-negative analysis uysing a Thermo Scientific Vanquish Duo LC interfaced to a Thermo Scientific Q-Exactive HFX with electrospray ionization source operated in positive mode. Samples were maintained at 4C in the autosampler module. For C18-pos separation, 5 uL of sample was injected onto a C18 columns (50 mm × 2.1 mm, 5 µm particle size, Higgins Analytical Inc) maintained at 30C. Separation occurred using Mobile phase A consisted of water with 0.1% formic acid and Mobile phase B consisted of Acetonitrile with 0.1% formic acid. Flow rate was held at at 0.4 ml/min for 1.5 mins, and increased to 0.5 ml/min. Solvent gradients were as follows: 85% solvent A, hold for 1.5 min; linear decrease to 5% solvent A at 5 minutes; hold for 2.5 min, for a total run time of 7.5 min Data was acquired with a mass range of 85-1275 m/z.
Instrument Name:Thermo Vanquish
Column Name:Higgins Analytical Targa C18 (50 x 2.1mm,5um)
Column Temperature:30C
Flow Rate:0.4-0.5 mL/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Analytical Time:7.5 min
Chromatography Type:Reversed phase
  
Chromatography ID:CH002043
Chromatography Summary:Sample extracts were analyzed using an ultra-high performance liquid chromatography (UHPLC) equipped with dual pumps for both C18-pos and C18-negative analysis using a Thermo Scientific Vanquish Duo LC interfaced to a Thermo Scientific Q-Exactive HFX with electrospray ionization source operated in negative mode. Samples were maintained at 4C in the autosampler module. For C18-neg separation, 5 uL of sample was injected onto a C18 columns (50 mm × 2.1 mm, 5 µm particle size, Higgins Analytical Inc) maintained at 30C. Separation occurred using Mobile phase A consisted of water with 10mM ammonium acetate and Mobile phase B consisted of Acetonitrile. Flow rate was held at at 0.4 ml/min for 1.5 mins, and increased to 0.5 ml/min. Solvent gradients were as follows: 85% solvent A, hold for 1.5 min; linear decrease to 5% solvent A at 5 minutes; hold for 2.5 min, for a total run time of 7.5 min Data was acquired with a mass range of 85-1275 m/z.
Instrument Name:Thermo Vanquish
Column Name:Higgins Analytical Targa C18 (50 x 2.1mm,5um)
Column Temperature:30C
Flow Rate:0.4-0.5 mL/min
Solvent A:100% water; 10mM ammonium acetate
Solvent B:100% acetonitrile
Analytical Time:7.5 min
Chromatography Type:Reversed phase