MB Sample ID: SA165094

Local Sample ID:LP27_pre_CSF_M
Subject ID:SU001857
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:25(IQR 22-31)
Gender:Male and female
Human Race:European
Human Medications:None
Human Prescription Otc:None
Human Smoking Status:None
Human Alcohol Drug Use:None

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002890 AN002891
Analysis type MS MS
Chromatography type HILIC Reversed phase
Chromatography system Shimadzu 20AD Shimadzu 20AD
Column Shodex NH2P-40 2E (250 x 2mm,4um) Raptor Biphenyl (150 × 2.1 mm,2.7um)
MS Type ESI ESI
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name ABI Sciex 5500 QTrap ABI Sciex 5500 QTrap
Ion Mode UNSPECIFIED UNSPECIFIED
Units peak area peak area

Chromatography:

Chromatography ID:CH002142
Chromatography Summary:Ten µL of the extract was injected into the column through a CTC PAL autosampler. The samples were separated in HILIC mode using a polymer-based NH2 column (250 × 2 mm, 4 µm) (Asahipak NH2P-40 2E, Shodex, Japan). The optimal LC conditions were as follows: Mobile phase A: 95% H2O with 20 mM (NH4)2CO3 and 5% ACN, pH 9.8. Mobile phase B: 100% ACN. The gradient was: 0 - 3.5 min 95% B, 3.6 - 8 min 85% B, 8.1 - 13 min 75% B, 14 - 30 min 0% B, 31 - 41 min 95% B, 41.1 min stop. The flow rate was 200 µL/min, and the column temperature was held at 25 ºC.
Instrument Name:Shimadzu 20AD
Column Name:Shodex NH2P-40 2E (250 x 2mm,4um)
Column Pressure:900 psi - 2400 psi
Column Temperature:25
Flow Gradient:Constant
Flow Rate:200 µL/min
Injection Temperature:4
Sample Injection:10 uL
Solvent A:95% water/5% acetonitrile; 20 mM ammonium acetate, pH 9.8
Solvent B:100% acetonitrile
Analytical Time:45 min
Oven Temperature:25
Sample Loop Size:10
Sample Syringe Size:100
Chromatography Type:HILIC
  
Chromatography ID:CH002143
Chromatography Summary:Ten µL of the extract was injected into the column through a CTC PAL autosampler. The samples were separated in the RP model using a Raptor Biphenyl column (150 × 2.1 mm, 2.7 µm) (Restek, PA). The LC conditions were as follows: Mobile phase A: 90% H2O with 0.1% formic acid and 10% MEOH, pH 4.0. Mobile phase B: MEOH-IPA (50:50, v/v) with 0.1% formic acid. The gradient was: 0 - 2 min 10% B, 2.1 - 4 min 40% B, 4 -12 min, linear ramping up to 100% B, 12 – 18 min 100% B, 19 - 24 min 10% B, 24.1 min stop. The flow rate was 250 µL/min, and the column temperature was controlled at 40 ºC.
Instrument Name:Shimadzu 20AD
Column Name:Raptor Biphenyl (150 × 2.1 mm,2.7um)
Column Pressure:2800 psi - 4200 psi
Column Temperature:40
Flow Gradient:Constant
Flow Rate:250 µL/min
Injection Temperature:4
Sample Injection:10 uL
Solvent A:90% water/10% methanol; 0.1% formic acid, pH 4.0
Solvent B:50% methanol/50% isopropanol; 0.1% formic acid
Analytical Time:25 min
Oven Temperature:40
Sample Loop Size:10
Sample Syringe Size:100
Chromatography Type:Reversed phase