Return to study ST002159 main page

MB Sample ID: SA207087

Local Sample ID:170821_Smp_1545_B
Subject ID:SU002245
Subject Type:Cultured cells
Subject Species:Marine Plankton

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003535 AN003536 AN003537 AN003538
Analysis type MS MS MS MS
Chromatography type HILIC HILIC HILIC Reversed phase
Chromatography system Waters Acquity I-Class Waters Acquity I-Class Waters Acquity I-Class Waters Acquity I-Class
Column SeQuant ZIC-pHILIC (150 x 2.1mm,5um) SeQuant ZIC-pHILIC (150 x 2.1mm,5um) SeQuant ZIC-pHILIC (150 x 2.1mm,5um) Waters Acquity UPLC HSS Cyano (100 x 2.1 mm,1.8um)
MS Type ESI ESI ESI ESI
MS instrument type Triple quadrupole Orbitrap Orbitrap Orbitrap
MS instrument name Waters Xevo-TQ-S Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode UNSPECIFIED POSITIVE NEGATIVE POSITIVE
Units presence (1), absence (0), or background level (NA) presence (1), absence (0), or background level (NA) presence (1), absence (0), or background level (NA) presence (1), absence (0), or background level (NA)

Chromatography:

Chromatography ID:CH002611
Chromatography Summary:For HILIC chromatography, a SeQuant ZIC-pHILIC column (5 µm particle size, 2.1 mm x 150 mm, from Millipore) was used with 10 mM ammonium carbonate in 85:15 acetonitrile to water (Solvent A) and 10 mM ammonium carbonate in 60:40 water to acetonitrile (Solvent B) at a flow rate of 0.15 mL/min.
Methods Filename:CH_Ingalls_LC_protocol.pdf
Instrument Name:Waters Acquity I-Class
Column Name:SeQuant ZIC-pHILIC (150 x 2.1mm,5um)
Column Temperature:30
Flow Rate:0.15 mL/min
Solvent A:85% acetonitrile/15% water; 10 mM ammonium carbonate
Solvent B:40% acetonitrile/60% water; 10 mM ammonium carbonate
Chromatography Type:HILIC
  
Chromatography ID:CH002612
Chromatography Summary:For reversed phase (RP) chromatography, a Waters Acquity UPLC HSS Cyano column (1.8 µm particle size, 2.1 mm x 100 mm) equipped with a Waters Acquity UPLC HSS Cyano guard column (1.8 µm particle size, 2.1 mm x 5 mm) was used with 0.1% formic acid in water (Solvent A) and 0.1% formic acid in acetonitrile (Solvent B) at a flow rate of 0.4 mL/ min.
Methods Filename:CH_Ingalls_LC_protocol.pdf
Instrument Name:Waters Acquity I-Class
Column Name:Waters Acquity UPLC HSS Cyano (100 x 2.1 mm,1.8um)
Column Temperature:35
Flow Rate:0.4 mL/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:Reversed phase