Return to study ST000040 main page

MB Sample ID: SA001764

Local Sample ID:Control_4S
Subject ID:SU000057
Subject Type:Invertebrate
Subject Species:Caenorhabditis elegans
Taxonomy ID:6239
Genotype Strain:N2
Age Or Age Range:Young Adult
Gender:Hermaphrodite
Species Group:Invertebrate

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000060 AN000061
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Accela 1250 Thermo Accela 1250
Column Thermo Scientific Gold aQ Thermo Scientific Gold aQ
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Peak area Peak area

MS:

MS ID:MS000041
Analysis ID:AN000060
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Samples were analyzed using a mass range of m/z 70-800 in positive and negative ionization mode, externally calibrated, using a Thermo Scientific Q-Exactive Orbitrap mass spectrometer equipped with an Open Accela autosampler and an Accela 1250 pump (San Jose, CA). The Q-Exactive was equipped with a heated electrospray ionization (HESI) source, which operated at a spray temperature of 500 °C, a spray voltage of 3 kV, and sheath and auxiliary gas flow rates of 60 and 10 arbitrary units, respectively. Features were extracted from the ms data using proprietary MATLAB IROA scripts. Ratios for each feature (heatshock/control) were calculated for each replicate. Ratios were normalized by setting the median log-fold change for each sample to zero
Ion Mode:POSITIVE
Ion Source Temperature:500 °C
Ion Spray Voltage:3 kV
Mass Accuracy:1.5 ppm
Scan Range Moverz:70-1000
  
MS ID:MS000042
Analysis ID:AN000061
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Samples were analyzed using a mass range of m/z 70-800 in positive and negative ionization mode, externally calibrated, using a Thermo Scientific Q-Exactive Orbitrap mass spectrometer equipped with an Open Accela autosampler and an Accela 1250 pump (San Jose, CA). The Q-Exactive was equipped with a heated electrospray ionization (HESI) source, which operated at a spray temperature of 500 °C, a spray voltage of 3 kV, and sheath and auxiliary gas flow rates of 60 and 10 arbitrary units, respectively. Features were extracted from the ms data using proprietary MATLAB IROA scripts. Ratios for each feature (heatshock/control) were calculated for each replicate. Ratios were normalized by setting the median log-fold change for each sample to zero
Ion Mode:NEGATIVE
Ion Source Temperature:500 °C
Ion Spray Voltage:3 kV
Mass Accuracy:1.5 ppm
Scan Range Moverz:70-1000
  logo