Return to study ST000899 main page

MB Sample ID: SA052836

Local Sample ID:303
Subject ID:SU000936
Subject Type:Human serum
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001462 AN001463 AN001464 AN001465
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters Acquity BEH C18 (100 x 2.1mm,1.7um) Waters Acquity BEH C18 (100 x 2.1mm,1.7um) Waters Acquity BEH C18 (100 x 2.1mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units raw area counts raw area counts raw area counts raw area counts

MS:

MS ID:MS001350
Analysis ID:AN001462
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Waters ACQUITY ultra-performance liquid chromatography (UPLC) Thermo Scientific Q-Exactive high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution
Ion Mode:POSITIVE
Resolution Setting:35,000
  
MS ID:MS001351
Analysis ID:AN001463
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Waters ACQUITY ultra-performance liquid chromatography (UPLC) Thermo Scientific Q-Exactive high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution
Ion Mode:POSITIVE
Resolution Setting:35,000
  
MS ID:MS001352
Analysis ID:AN001464
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Waters ACQUITY ultra-performance liquid chromatography (UPLC) Thermo Scientific Q-Exactive high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution
Ion Mode:NEGATIVE
Resolution Setting:35,000
  
MS ID:MS001353
Analysis ID:AN001465
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Waters ACQUITY ultra-performance liquid chromatography (UPLC) Thermo Scientific Q-Exactive high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution
Ion Mode:NEGATIVE
Resolution Setting:35,000