Return to study ST001212 main page

MB Sample ID: SA087452

Local Sample ID:V104
Subject ID:SU001298
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:4-8 months
Gender:Male and female
Human Ethnicity:Mainly Caucasian
Human Trial Type:RCT

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002044 AN002045 AN002046 AN002047
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units peak area peak area peak area peak area

MS:

MS ID:MS001896
Analysis ID:AN002044
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The MS analysis alternated between MS and data-dependent MSn scans using dynamic exclusion. The scan range varied slighted between methods but covered 70-1000 m/z. Raw data was extracted, peak-identified and QC processed using Metabolon’s hardware and software. Compounds were identified by comparison to library entries of purified standards or recurrent unknown entities.
Ion Mode:POSITIVE
  
MS ID:MS001897
Analysis ID:AN002045
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The MS analysis alternated between MS and data-dependent MSn scans using dynamic exclusion. The scan range varied slighted between methods but covered 70-1000 m/z. Raw data was extracted, peak-identified and QC processed using Metabolon’s hardware and software. Compounds were identified by comparison to library entries of purified standards or recurrent unknown entities.
Ion Mode:POSITIVE
  
MS ID:MS001898
Analysis ID:AN002046
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The MS analysis alternated between MS and data-dependent MSn scans using dynamic exclusion. The scan range varied slighted between methods but covered 70-1000 m/z. Raw data was extracted, peak-identified and QC processed using Metabolon’s hardware and software. Compounds were identified by comparison to library entries of purified standards or recurrent unknown entities.
Ion Mode:NEGATIVE
  
MS ID:MS001899
Analysis ID:AN002047
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The MS analysis alternated between MS and data-dependent MSn scans using dynamic exclusion. The scan range varied slighted between methods but covered 70-1000 m/z. Raw data was extracted, peak-identified and QC processed using Metabolon’s hardware and software. Compounds were identified by comparison to library entries of purified standards or recurrent unknown entities.
Ion Mode:NEGATIVE
  logo