MB Sample ID: SA095968

Local Sample ID:S5D
Subject ID:SU001397
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Genotype Strain:C57BL/6

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002199 AN002200 AN002201
Analysis type MS MS MS
Chromatography type HILIC HILIC HILIC
Chromatography system Agilent 1290 Infinity Agilent 1290 Infinity Agilent 1290 Infinity
Column Agilent HILIC Plus RRHD (100 x 2.1mm, 1.8um) Agilent HILIC Plus RRHD (100 x 2.1mm, 1.8um) Agilent HILIC Plus RRHD (100 x 2.1mm, 1.8um)
MS Type ESI ESI ESI
MS instrument type Triple quadrupole Triple quadrupole Triple quadrupole
MS instrument name Agilent 6490 QQQ Agilent 6490 QQQ Agilent 6490 QQQ
Ion Mode UNSPECIFIED POSITIVE UNSPECIFIED
Units intensity intensity intensity

MS:

MS ID:MS002045
Analysis ID:AN002199
Instrument Name:Agilent 6490 QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Targeted lipidomics were performed on an Agilent Technologies 1290 Infinity UHPLC system with an Agilent HILIC Plus RRHD 2.1×100 mm 1.8-micron column, coupled online to an Agilent 6490A Triple Quadrupole mass spectrometer with iFunnel and Agilent Jet Stream (AJS) electrospray ionization (ESI) source, operated in dynamic MRM mode. The source nitrogen gas temperature was set to 250°C at a flow of 15 L/min and a sheath gas temperature of 400°C at a flow of 12 L/min. The capillary voltage was set to 4000 V for positive mode and 5000 V for negative mode and the nebulizer operated at 30 psi. Ion funnel high and low pressure in positive and negative mode were 150 and 120. Check tunes were performed in wide, unit and enhanced modes prior to each experiment to confirm the performance of the mass spectrometer. The quadrupole was tuned to reference masses 118.09, 322.05, 622.03, 922.01 and 1221.99 in positive ionization mode; 112.99, 302.00, 601.98, 1033.99 and 1333.97 in negative ionization mode.
Ion Mode:UNSPECIFIED
  
MS ID:MS002046
Analysis ID:AN002200
Instrument Name:Agilent 6490 QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Targeted lipidomics were performed on an Agilent Technologies 1290 Infinity UHPLC system with an Agilent HILIC Plus RRHD 2.1×100 mm 1.8-micron column, coupled online to an Agilent 6490A Triple Quadrupole mass spectrometer with iFunnel and Agilent Jet Stream (AJS) electrospray ionization (ESI) source, operated in dynamic MRM mode. The source nitrogen gas temperature was set to 250°C at a flow of 15 L/min and a sheath gas temperature of 400°C at a flow of 12 L/min. The capillary voltage was set to 4000 V for positive mode and 5000 V for negative mode and the nebulizer operated at 30 psi. Ion funnel high and low pressure in positive and negative mode were 150 and 120. Check tunes were performed in wide, unit and enhanced modes prior to each experiment to confirm the performance of the mass spectrometer. The quadrupole was tuned to reference masses 118.09, 322.05, 622.03, 922.01 and 1221.99 in positive ionization mode; 112.99, 302.00, 601.98, 1033.99 and 1333.97 in negative ionization mode.
Ion Mode:POSITIVE
  
MS ID:MS002047
Analysis ID:AN002201
Instrument Name:Agilent 6490 QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Targeted lipidomics were performed on an Agilent Technologies 1290 Infinity UHPLC system with an Agilent HILIC Plus RRHD 2.1×100 mm 1.8-micron column, coupled online to an Agilent 6490A Triple Quadrupole mass spectrometer with iFunnel and Agilent Jet Stream (AJS) electrospray ionization (ESI) source, operated in dynamic MRM mode. The source nitrogen gas temperature was set to 250°C at a flow of 15 L/min and a sheath gas temperature of 400°C at a flow of 12 L/min. The capillary voltage was set to 4000 V for positive mode and 5000 V for negative mode and the nebulizer operated at 30 psi. Ion funnel high and low pressure in positive and negative mode were 150 and 120. Check tunes were performed in wide, unit and enhanced modes prior to each experiment to confirm the performance of the mass spectrometer. The quadrupole was tuned to reference masses 118.09, 322.05, 622.03, 922.01 and 1221.99 in positive ionization mode; 112.99, 302.00, 601.98, 1033.99 and 1333.97 in negative ionization mode.
Ion Mode:UNSPECIFIED