Return to study ST001331 main page

MB Sample ID: SA096519

Local Sample ID:OXGF14b-2-24h-1
Subject ID:SU001405
Subject Type:Plant
Subject Species:Oryza sativa Japonica Group
Taxonomy ID:39947

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002219 AN002220
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters CORTECS C18 (150 x 2.1mm,2.7um) Waters CORTECS C18 (150 x 2.1mm,2.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Fusion Tribrid Orbitrap Thermo Fusion Tribrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Relative content Relative content

MS:

MS ID:MS002065
Analysis ID:AN002219
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The spray voltage was set to 3500 V in the positive-ion modes, with the following ion-source properties: sheath gas, 45 Arbs; auxiliary gas, 10 Arbs; sweep gas, 0 Arbs; ion-transfer tube temperature, 320 °C; vaporizer temp, 350 °C. All FTMS data were acquired using the following conditions: detector type, orbitrap; orbitrap resolution, 120000; scan range was set to m/z 200-1200. The AGC was set at 5.0 e5 and the maximum injection time was set to 100 ms. RF lens was set to 60%, and the microscans was 1. data type, profile. All FTMS2 data were acquired using the following conditions: isolation mode, quadrupole; isolation window, 1 m/z; detector type, orbitrap; scan range, auto; AGC target, 5.0 e4; maximum injection time, 100 ms; microscans, 1; orbitrap resolution, 30000; first mass, 50 m/z; data type, profile. The HCD collision energy was set to 25% with ± HCD collision energy was set 5% in positive mode, and the HCD collision energy was set to 30% with ± HCD collision energy was set 5% in negative mode. All data was acquired by the Xcalibur 4.1 software (Thermo Fisher Scientific, USA). Thermo Scientific™ LipidSearch™ 5.0 software was used for lipidome data processing.
Ion Mode:POSITIVE
  
MS ID:MS002066
Analysis ID:AN002220
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The spray voltage was set to -3000 V in the negative-ion modes, with the following ion-source properties: sheath gas, 45 Arbs; auxiliary gas, 10 Arbs; sweep gas, 0 Arbs; ion-transfer tube temperature, 320 °C; vaporizer temp, 350 °C. All FTMS data were acquired using the following conditions: detector type, orbitrap; orbitrap resolution, 120000; scan range was set to m/z 200-1200. The AGC was set at 5.0 e5 and the maximum injection time was set to 100 ms. RF lens was set to 60%, and the microscans was 1. data type, profile. All FTMS2 data were acquired using the following conditions: isolation mode, quadrupole; isolation window, 1 m/z; detector type, orbitrap; scan range, auto; AGC target, 5.0 e4; maximum injection time, 100 ms; microscans, 1; orbitrap resolution, 30000; first mass, 50 m/z; data type, profile. The HCD collision energy was set to 25% with ± HCD collision energy was set 5% in positive mode, and the HCD collision energy was set to 30% with ± HCD collision energy was set 5% in negative mode. All data was acquired by the Xcalibur 4.1 software (Thermo Fisher Scientific, USA). Thermo Scientific™ LipidSearch™ 5.0 software was used for lipidome data processing.
Ion Mode:NEGATIVE