Return to study ST001356 main page
MB Sample ID: SA098661
Local Sample ID: | S1R1 |
Subject ID: | SU001430 |
Subject Type: | Other |
Subject Species: | Ilyonectria mors-panacis;Ilyonectria rufa;Ilyonectria robusta;Ilyonectria torresensis;Ilyonectria estremocensis;Neonectria obtusispora |
Taxonomy ID: | 1079131;1079113;1079257;1199091;1079267;78417 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002255 | AN002256 | AN002257 | AN002258 | AN002259 |
---|---|---|---|---|---|
Analysis type | MS | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | HILIC | HILIC | HILIC |
Chromatography system | Waters Acquity I-Class | Waters Acquity I-Class | Waters Acquity I-Class | Waters Acquity I-Class | Waters Acquity I-Class |
Column | Waters Acquity UPLC HSS Cyano (CN) ( 50 x 2.1mm,1.8um) | Waters Acquity UPLC HSS Cyano (CN) ( 50 x 2.1mm,1.8um) | SeQuant ZIC-pHILIC (150 x 2.1mm,5um) | SeQuant ZIC-pHILIC (150 x 2.1mm,5um) | SeQuant ZIC-pHILIC (150 x 2.1mm,5um) |
MS Type | ESI | ESI | ESI | ESI | ESI |
MS instrument type | Triple quadrupole | Orbitrap | Triple quadrupole | Triple quadrupole | Orbitrap |
MS instrument name | Waters Xevo-TQ-S | Thermo Q Exactive HF hybrid Orbitrap | Waters Xevo-TQ-S | Waters Xevo-TQ-S | Thermo Q Exactive HF hybrid Orbitrap |
Ion Mode | POSITIVE | POSITIVE | POSITIVE | NEGATIVE | POSITIVE |
Units | Normalized Peak Area Per L Seawater Filtered | Normalized Peak Area Per L Seawater Filtered | Normalized Peak Area Per L Seawater Filtered | Normalized Peak Area Per L Seawater Filtered | Normalized Peak Area per L of SW filtered |
MS:
MS ID: | MS002099 |
Analysis ID: | AN002255 |
Instrument Name: | Waters Xevo-TQ-S |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | See File |
Ion Mode: | POSITIVE |
Acquisition Parameters File: | Ingalls_Metabolomics_MS_Parameters_2015.txt |
MS ID: | MS002100 |
Analysis ID: | AN002256 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | See File |
Ion Mode: | POSITIVE |
Acquisition Parameters File: | Ingalls_Metabolomics_MS_Parameters_2015.txt |
MS ID: | MS002101 |
Analysis ID: | AN002257 |
Instrument Name: | Waters Xevo-TQ-S |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | See File |
Ion Mode: | POSITIVE |
Acquisition Parameters File: | Ingalls_Metabolomics_MS_Parameters_2015.txt |
MS ID: | MS002102 |
Analysis ID: | AN002258 |
Instrument Name: | Waters Xevo-TQ-S |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | See File |
Ion Mode: | NEGATIVE |
Acquisition Parameters File: | Ingalls_Metabolomics_MS_Parameters_2015.txt |
MS ID: | MS002103 |
Analysis ID: | AN002259 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | See File |
Ion Mode: | POSITIVE |
Acquisition Parameters File: | Ingalls_Metabolomics_MS_Parameters_2015.txt |