Return to study ST001427 main page

MB Sample ID: SA120142

Local Sample ID:C2
Subject ID:SU001501
Subject Type:Mammal
Subject Species:Sus scrofa
Taxonomy ID:9823

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002385 AN002386
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 1200 Agilent 1200
Column Agilent Zorbax SB-C18 (100 x 2.1mm,3.5um) Agilent Zorbax SB-C18 (100 x 2.1mm,3.5um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6530 QTOF Agilent 6530 QTOF
Ion Mode POSITIVE NEGATIVE
Units Peak Area Peak Area

MS:

MS ID:MS002227
Analysis ID:AN002385
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:LC-MS.pdf with all the details related to the analysis of plasma samples is uploaded. Then, XCMS was used to process data by using the Isotopologue Parameters Optimization (IPO) package following the criteria reported by Albóniga et al. (Alboniga OE, Gonzalez O, Alonso RM, Xu Y, Goodacre R. Optimization of XCMS parameters for LC-MS metabolomics: An assessment of automated versus manual tuning and its effect on the final results. Metabolomics. 2020;16(1):14-020-1636-9) Finally, Plasma data matrix was processed with Matlab using the toolbox freely available online at https://github.com/Biospec/cluster-toolbox-v2.0. Intensity drop was corrected with the QC correction function included in the toolbox and then autoscaling was applied. Then multivariate and univariate analysis were carried out.
Ion Mode:POSITIVE
  
MS ID:MS002228
Analysis ID:AN002386
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:LC-MS.pdf with all the details related to the analysis of plasma samples is uploaded. Then, XCMS was used to process data by using the Isotopologue Parameters Optimization (IPO) package following the criteria reported by Albóniga et al. (Alboniga OE, Gonzalez O, Alonso RM, Xu Y, Goodacre R. Optimization of XCMS parameters for LC-MS metabolomics: An assessment of automated versus manual tuning and its effect on the final results. Metabolomics. 2020;16(1):14-020-1636-9) Finally, Plasma data matrix was processed with Matlab using the toolbox freely available online at https://github.com/Biospec/cluster-toolbox-v2.0. Intensity drop was corrected with the QC correction function included in the toolbox and then logarithm scaling was applied. Then multivariate and univariate analysis were carried out.
Ion Mode:NEGATIVE