Return to study ST001427 main page
MB Sample ID: SA120149
Local Sample ID: | C8 |
Subject ID: | SU001501 |
Subject Type: | Mammal |
Subject Species: | Sus scrofa |
Taxonomy ID: | 9823 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002385 | AN002386 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Agilent 1200 | Agilent 1200 |
Column | Agilent Zorbax SB-C18 (100 x 2.1mm,3.5um) | Agilent Zorbax SB-C18 (100 x 2.1mm,3.5um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | Agilent 6530 QTOF | Agilent 6530 QTOF |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak Area | Peak Area |
MS:
MS ID: | MS002227 |
Analysis ID: | AN002385 |
Instrument Name: | Agilent 6530 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | LC-MS.pdf with all the details related to the analysis of plasma samples is uploaded. Then, XCMS was used to process data by using the Isotopologue Parameters Optimization (IPO) package following the criteria reported by Albóniga et al. (Alboniga OE, Gonzalez O, Alonso RM, Xu Y, Goodacre R. Optimization of XCMS parameters for LC-MS metabolomics: An assessment of automated versus manual tuning and its effect on the final results. Metabolomics. 2020;16(1):14-020-1636-9) Finally, Plasma data matrix was processed with Matlab using the toolbox freely available online at https://github.com/Biospec/cluster-toolbox-v2.0. Intensity drop was corrected with the QC correction function included in the toolbox and then autoscaling was applied. Then multivariate and univariate analysis were carried out. |
Ion Mode: | POSITIVE |
MS ID: | MS002228 |
Analysis ID: | AN002386 |
Instrument Name: | Agilent 6530 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | LC-MS.pdf with all the details related to the analysis of plasma samples is uploaded. Then, XCMS was used to process data by using the Isotopologue Parameters Optimization (IPO) package following the criteria reported by Albóniga et al. (Alboniga OE, Gonzalez O, Alonso RM, Xu Y, Goodacre R. Optimization of XCMS parameters for LC-MS metabolomics: An assessment of automated versus manual tuning and its effect on the final results. Metabolomics. 2020;16(1):14-020-1636-9) Finally, Plasma data matrix was processed with Matlab using the toolbox freely available online at https://github.com/Biospec/cluster-toolbox-v2.0. Intensity drop was corrected with the QC correction function included in the toolbox and then logarithm scaling was applied. Then multivariate and univariate analysis were carried out. |
Ion Mode: | NEGATIVE |