MB Sample ID: SA125944
Local Sample ID: | SC_20190605_RPLCp_FMS_Embryo_S8 |
Subject ID: | SU001568 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002476 | AN002477 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Thermo Hypersil Gold (100 x 2.1mm,1.9um) | Thermo Hypersil Gold (100 x 2.1mm,1.9um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap |
Ion Mode | POSITIVE | POSITIVE |
Units | peak area | peak area |
MS:
MS ID: | MS002296 |
Analysis ID: | AN002476 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Full MS analyses were acquired over a mass range of m/z 70-1050 under an ESI positive profile mode. Full mass scan was used at a resolution of 120,000 with a scan rate at ∼3.5 Hz Raw data were imported, processed, normalized, and reviewed using Progenesis QI v.2.1 (Non-linear Dynamics, Newcastle, UK). All FMS sample runs were aligned against a FMS QC pool reference, with alignment to the reference being ≥ 96%, demonstrating the reproducibility of the RPLC column separation method. Peak picking, with a minimum threshold of 100,000 ion intensity, was performed for individual aligned runs based on an aggregate run (representative of all ion peaks detected in all samples). |
Ion Mode: | POSITIVE |
MS ID: | MS002297 |
Analysis ID: | AN002477 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Full MS analyses were acquired over a mass range of m/z 70-1050 under an ESI positive profile mode. Full mass scan was used at a resolution of 120,000 with a scan rate at ∼3.5 Hz Raw data were imported, processed, normalized, and reviewed using Progenesis QI v.2.1 (Non-linear Dynamics, Newcastle, UK). All FMS sample runs were aligned against a FMS QC pool reference, with alignment to the reference being ≥ 96%, demonstrating the reproducibility of the RPLC column separation method. Peak picking, with a minimum threshold of 100,000 ion intensity, was performed for individual aligned runs based on an aggregate run (representative of all ion peaks detected in all samples). |
Ion Mode: | POSITIVE |