MB Sample ID: SA157150

Local Sample ID:C-23X77-BR-00
Subject ID:SU001769
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Gender:Female

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002762 AN002763
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Higgins Analytical Targa C18 (50 x 2.1mm,5um) Higgins Analytical Targa C18 (50 x 2.1mm,5um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q-Exactive HFX Thermo Q-Exactive HFX
Ion Mode POSITIVE NEGATIVE
Units Peak intensity Peak intensity

MS:

MS ID:MS002559
Analysis ID:AN002762
Instrument Name:Thermo Q-Exactive HFX
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Analysis was performed for all batches in each mode. Database dependent targeted identification: Metabolites were identified based upon in-house database matching considering retention time, accurate mass, and MSMS matching (when available) matching with pure standards analyzed under the same conditions. Untargeted feature tables were generated by converting .RAW files to mzXML, and extracted using apLCMS at 5 different peak detection parameters. The resulting tables were merged using xMSanalyzer to remove redundant peaks, and batch corrected using ComBAT. All scripts for data extraction are included in the raw datafile uploads.
Ion Mode:POSITIVE
Capillary Temperature:300
Capillary Voltage:35 (S-Lens RF)
Dry Gas Flow:45
Ionization:Postive
Source Temperature:250
Spray Voltage:3500
Processing Parameters File:apLCMSv6.6.8_runscript_c18-pos_HRE0010_02Dec2020.r
xMSanalyzer_v2.0.8_HRE0010-C18pos_18Dec2020.r
  
MS ID:MS002560
Analysis ID:AN002763
Instrument Name:Thermo Q-Exactive HFX
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Analysis was performed for all batches in each mode. Database dependent targeted identification: Metabolites were identified based upon in-house database matching considering retention time, accurate mass, and MSMS matching (when available) matching with pure standards analyzed under the same conditions. Untargeted feature tables were generated by converting .RAW files to mzXML, and extracted using apLCMS at 5 different peak detection parameters. The resulting tables were merged using xMSanalyzer to remove redundant peaks, and batch corrected using ComBAT. All scripts for data extraction are included in the raw datafile uploads.
Ion Mode:NEGATIVE
Capillary Temperature:300
Capillary Voltage:4000 (S-Lens RF)
Dry Gas Flow:45
Ionization:Negative
Source Temperature:250
Spray Voltage:-4000
Processing Parameters File:apLCMSv6.6.8_runscript_c18-neg_HRE0010_02Dec2020.r
xMSanalyzer_v2.0.8_HRE0010-C18neg_18Dec2020.r