Return to study ST001935 main page

MB Sample ID: SA181885

Local Sample ID:HFD-PB2
Subject ID:SU002013
Subject Type:Mammal
Subject Species:Macaca fascicularis
Taxonomy ID:9541
Age Or Age Range:16.3 - 18.8 yo
Weight Or Weight Range:5.73 - 10.56 kg
Gender:Male
Animal Animal Supplier:Guangzhou Huazhen Biosciences Co., Ltd, Guangzhou
Animal Housing:Guangzhou Huazhen Biosciences Co., Ltd, Guangzhou
Animal Light Cycle:12-h/12-h light-dark cycle
Animal Feed:normal food (19.26 % protein, 5% fat, no sugar, and no cholesterol), or high-fat and high-sugar (HFHS) food (≥ 30% sugar, ≥ 15% fat, ≥ 10.5% protein, and ≥ 0.5% cholesterol)
Animal Inclusion Criteria:spontaneous diabetes mellitus and HFHS food-fed

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003145 AN003146 AN003147 AN003148
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase Reversed phase
Chromatography system Shim-pack UFLC SHIMADZU CBM A system Shim-pack UFLC SHIMADZU CBM A system Shim-pack UFLC SHIMADZU CBM A system Shim-pack UFLC SHIMADZU CBM A system
Column Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um)
MS Type EI EI EI EI
MS instrument type Triple quadrupole Triple quadrupole Triple quadrupole Triple quadrupole
MS instrument name ABI Sciex 6500 QTrap ABI Sciex 6500 QTrap ABI Sciex 6500 QTrap ABI Sciex 6500 QTrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Peak area Peak area Peak area Peak area

MS:

MS ID:MS002925
Analysis ID:AN003145
Instrument Name:ABI Sciex 6500 QTrap
Instrument Type:Triple quadrupole
MS Type:EI
MS Comments:LIT and triple quadrupole (QQQ) scans were acquired in both positive and negative ion modes under the control of Analyst 1.6.3 software (Sciex, Washington, USA). The ion spray voltage (IS) of the ESI source was 5500 and -4500 V for positive and negative modes, respectively. Source temperature was set at 500 C, ion source gas I (GSI), gas II (GSII), curtain gas (CUR) at 55, 60, and 25.0 psi, respectively, and collision gas (CAD) high. Instrument tuning and mass calibration in QQQ and LIT modes were performed with 10 and 100 μmol/L polypropylene glycol solutions, respectively. Specific sets of multiple reaction monitoring (MRM) transitions of various periods of retention time were monitored according to an in-house library of metabolites.
Ion Mode:POSITIVE
  
MS ID:MS002926
Analysis ID:AN003146
Instrument Name:ABI Sciex 6500 QTrap
Instrument Type:Triple quadrupole
MS Type:EI
MS Comments:LIT and triple quadrupole (QQQ) scans were acquired in both positive and negative ion modes under the control of Analyst 1.6.3 software (Sciex, Washington, USA). The ion spray voltage (IS) of the ESI source was 5500 and -4500 V for positive and negative modes, respectively. Source temperature was set at 500 C, ion source gas I (GSI), gas II (GSII), curtain gas (CUR) at 55, 60, and 25.0 psi, respectively, and collision gas (CAD) high. Instrument tuning and mass calibration in QQQ and LIT modes were performed with 10 and 100 μmol/L polypropylene glycol solutions, respectively. Specific sets of multiple reaction monitoring (MRM) transitions of various periods of retention time were monitored according to an in-house library of metabolites.
Ion Mode:NEGATIVE
  
MS ID:MS002927
Analysis ID:AN003147
Instrument Name:ABI Sciex 6500 QTrap
Instrument Type:Triple quadrupole
MS Type:EI
MS Comments:LIT and triple quadrupole (QQQ) scans were acquired in both positive and negative ion modes under the control of Analyst 1.6.3 software (Sciex, Washington, USA). The ion spray voltage (IS) of the ESI source was 5500 and -4500 V for positive and negative modes, respectively. Source temperature was set at 500 C, ion source gas I (GSI), gas II (GSII), curtain gas (CUR) at 55, 60, and 25.0 psi, respectively, and collision gas (CAD) high. Instrument tuning and mass calibration in QQQ and LIT modes were performed with 10 and 100 μmol/L polypropylene glycol solutions, respectively. Specific sets of multiple reaction monitoring (MRM) transitions of various periods of retention time were monitored according to an in-house library of metabolites.
Ion Mode:POSITIVE
  
MS ID:MS002928
Analysis ID:AN003148
Instrument Name:ABI Sciex 6500 QTrap
Instrument Type:Triple quadrupole
MS Type:EI
MS Comments:LIT and triple quadrupole (QQQ) scans were acquired in both positive and negative ion modes under the control of Analyst 1.6.3 software (Sciex, Washington, USA). The ion spray voltage (IS) of the ESI source was 5500 and -4500 V for positive and negative modes, respectively. Source temperature was set at 500 C, ion source gas I (GSI), gas II (GSII), curtain gas (CUR) at 55, 60, and 25.0 psi, respectively, and collision gas (CAD) high. Instrument tuning and mass calibration in QQQ and LIT modes were performed with 10 and 100 μmol/L polypropylene glycol solutions, respectively. Specific sets of multiple reaction monitoring (MRM) transitions of various periods of retention time were monitored according to an in-house library of metabolites.
Ion Mode:NEGATIVE
  logo