MB Sample ID: SA188863

Local Sample ID:Pat_43_NEG
Subject ID:SU002097
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003284 AN003285
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Thermo Accucore C18 (100 x 2.1mm,2.6um) Thermo Accucore C18 (100 x 2.1mm,2.6um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Orbitrap ID-X tribrid Thermo Orbitrap ID-X tribrid
Ion Mode POSITIVE NEGATIVE
Units intensity intensity

MS:

MS ID:MS003055
Analysis ID:AN003284
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:HESI) source was operated at 3.5 kV and 2.5kV for positive and negative modes, respectively. Ion source sheath gas was set at 35 and auxiliary gas at 7. Ion transfer tube temperature was maintained at 275 °C while vaporizer temperature was maintained at 320 °C. The instrument was set to acquire over the m/z range 67-1000, in full MS mode (1 µscan) at a resolution of 60,000 at a normalized AGC Target of 25% and 50 milliseconds of maximum injection time was allowed. RF lens amplitude was set at 35%. Tandem MS/MS performed by applying quadrupole isolation with an isolation window of 1.6 m/z. Activation type was set at HCD and masses were fragmented with HCD Assisted Collision Energy (%) of 15,35,50. Fragment masses were detected by Orbitrap at a resolution of 15,000.
Ion Mode:POSITIVE
  
MS ID:MS003056
Analysis ID:AN003285
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:HESI) source was operated at 3.5 kV and 2.5kV for positive and negative modes, respectively. Ion source sheath gas was set at 35 and auxiliary gas at 7. Ion transfer tube temperature was maintained at 275 °C while vaporizer temperature was maintained at 320 °C. The instrument was set to acquire over the m/z range 67-1000, in full MS mode (1 µscan) at a resolution of 60,000 at a normalized AGC Target of 25% and 50 milliseconds of maximum injection time was allowed. RF lens amplitude was set at 35%. Tandem MS/MS performed by applying quadrupole isolation with an isolation window of 1.6 m/z. Activation type was set at HCD and masses were fragmented with HCD Assisted Collision Energy (%) of 15,35,50. Fragment masses were detected by Orbitrap at a resolution of 15,000.
Ion Mode:NEGATIVE