MB Sample ID: SA218527

Local Sample ID:D3_TS_A_Lip_Pos
Subject ID:SU002369
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:61-91
Gender:Female

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003728 AN003729 AN003730 AN003731
Analysis type MS MS MS MS
Chromatography type HILIC HILIC Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Waters Acquity BEH Amide (150 x 2.1mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Obitrap ID-X Tribrid Obitrap ID-X Tribrid Obitrap ID-X Tribrid Obitrap ID-X Tribrid
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Area integration Area integration Area integration Area integration

MS:

MS ID:MS003476
Analysis ID:AN003728
Instrument Name:Obitrap ID-X Tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Mass spectrometry (MS) data were acquired using the AcquieX acquisition workflow (data dependent analysis). The MS operating parameters were as follows: MS1 mass resolution 60K, for MS2 30K, stepped energy (HCD) 20, 25, 50, scan range 100-1000, RF len (%) 35, AGC gain, intensity threshold 2e4, 25% custom injection mode with an injection time of 54 ms. An extraction blank was used to create a background exclusion list and a pooled QC was used to create the inclusion list.
Ion Mode:POSITIVE
  
MS ID:MS003477
Analysis ID:AN003729
Instrument Name:Obitrap ID-X Tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Mass spectrometry (MS) data were acquired using the AcquieX acquisition workflow (data dependent analysis). The MS operating parameters were as follows: MS1 mass resolution 60K, for MS2 30K, stepped energy (HCD) 20, 25, 50, scan range 100-1000, RF len (%) 35, AGC gain, intensity threshold 2e4, 25% custom injection mode with an injection time of 54 ms. An extraction blank was used to create a background exclusion list and a pooled QC was used to create the inclusion list.
Ion Mode:NEGATIVE
  
MS ID:MS003478
Analysis ID:AN003730
Instrument Name:Obitrap ID-X Tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Mass spectrometry (MS) data were acquired using the AcquieX acquisition workflow (data dependent analysis). The MS operating parameters were as follows: MS1 mass resolution 60K, for MS2 30K, stepped energy (HCD) 20, 25, 50, scan range 100-1000, RF len (%) 35, AGC gain, intensity threshold 2e4, 25% custom injection mode with an injection time of 54 ms. An extraction blank was used to create a background exclusion list and a pooled QC was used to create the inclusion list.
Ion Mode:POSITIVE
  
MS ID:MS003479
Analysis ID:AN003731
Instrument Name:Obitrap ID-X Tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Mass spectrometry (MS) data were acquired using the AcquieX acquisition workflow (data dependent analysis). The MS operating parameters were as follows: MS1 mass resolution 60K, for MS2 30K, stepped energy (HCD) 20, 25, 50, scan range 100-1000, RF len (%) 35, AGC gain, intensity threshold 2e4, 25% custom injection mode with an injection time of 54 ms. An extraction blank was used to create a background exclusion list and a pooled QC was used to create the inclusion list.
Ion Mode:NEGATIVE