Return to study ST002330 main page

MB Sample ID: SA229752

Local Sample ID:HILIC-RN30-neg
Subject ID:SU002417
Subject Type:Plant
Subject Species:Brassica napus
Taxonomy ID:3708

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003801 AN003802 AN003803
Analysis type MS MS MS
Chromatography type HILIC HILIC Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS
Column Agilent InfinityLab Poroshell 120 HILIC-Z (100 x 2.1mm,2.7um) Agilent InfinityLab Poroshell 120 HILIC-Z (100 x 2.1mm,2.7um) Phenomonex Kinetex C18 (50 x 2.1mm,2.6um)
MS Type ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE NEGATIVE
Units normalized relative level normalized relative level normalized relative level

MS:

MS ID:MS003543
Analysis ID:AN003801
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Orbitrap QExactive was operated with a heated electrospray ionization (HESI) probe in positive mode. Temperatures of the HESI-II auxiliary gas heater and capillary were 450 and 300 °C, respectively, and the spray voltage was 3.9 kV. Sheath, auxiliary, and sweep gases were operated at 30, 8, and 0 (arbitrary units), respectively, and the S-lens RF level was 60. Each sample was analyzed using a mass range of m/z 70−900, and data were acquired at 70,000 resolution, automatic gain control (AGC) target of 1e6, and maximum injection time (IT) of 100 ms. Additionally, the top 10 data-dependent acquisition experiments were performed for the mixed sample from each group (HILIC and C18) to obtain compound MS/MS spectra. Processing of all full scan and ddMS2 data was conducted using the Xcalibur 4.1 software. Metabolites were identified by accurate mass, comparison of retention times to authentic standards or by accurate mass and comparison of fragmentation patterns to MS/MS databases (METLIN, PubChem). Metabolite relative concentration was normalized based on the average recoveries of 13C5-oT and 2H7-BAR as the internal standards
Ion Mode:POSITIVE
  
MS ID:MS003544
Analysis ID:AN003802
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Orbitrap QExactive was operated with a heated electrospray ionization (HESI) probe in negative mode. Temperatures of the HESI-II auxiliary gas heater and capillary were 450 and 300 °C, respectively, and the spray voltage was 3.9 kV. Sheath, auxiliary, and sweep gases were operated at 30, 8, and 0 (arbitrary units), respectively, and the S-lens RF level was 60. Each sample was analyzed using a mass range of m/z 70−900, and data were acquired at 70,000 resolution, automatic gain control (AGC) target of 1e6, and maximum injection time (IT) of 100 ms. Additionally, the top 10 data-dependent acquisition experiments were performed for the mixed sample from each group (HILIC and C18) to obtain compound MS/MS spectra. Processing of all full scan and ddMS2 data was conducted using the Xcalibur 4.1 software. Metabolites were identified by accurate mass, comparison of retention times to authentic standards or by accurate mass and comparison of fragmentation patterns to MS/MS databases (METLIN, PubChem). Metabolite relative concentration was normalized based on the average recoveries of 13C5-oT and 2H7-BAR as the internal standards
Ion Mode:NEGATIVE
  
MS ID:MS003545
Analysis ID:AN003803
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Orbitrap QExactive was operated with a heated electrospray ionization (HESI) probe in negative mode. Temperatures of the HESI-II auxiliary gas heater and capillary were 450 and 300 °C, respectively, and the spray voltage was 3.9 kV. Sheath, auxiliary, and sweep gases were operated at 30, 8, and 0 (arbitrary units), respectively, and the S-lens RF level was 60. Each sample was analyzed using a mass range of m/z 70−900, and data were acquired at 70,000 resolution, automatic gain control (AGC) target of 1e6, and maximum injection time (IT) of 100 ms. Additionally, the top 10 data-dependent acquisition experiments were performed for the mixed sample from each group (HILIC and C18) to obtain compound MS/MS spectra. Processing of all full scan and ddMS2 data was conducted using the Xcalibur 4.1 software. Metabolites were identified by accurate mass, comparison of retention times to authentic standards or by accurate mass and comparison of fragmentation patterns to MS/MS databases (METLIN, PubChem). Metabolite relative concentration was normalized based on the average recoveries of 13C5-oT and 2H7-BAR as the internal standards
Ion Mode:NEGATIVE