Combined analysis:

Analysis ID AN003842 AN003843 AN003844 AN003845
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase Reversed phase
Chromatography system Prominence XR Prominence XR Prominence XR Prominence XR
Column Targa C8, 2x10 mm, 5μ Luna C18 (150 x 2.1mm,3um) Targa C8, 2x10 mm, 5μ Luna C18 (150 x 2.1mm,3um)
MS Type ESI ESI ESI ESI
MS instrument type QTRAP QTRAP QTRAP QTRAP
MS instrument name ABI Sciex 5500 QTrap ABI Sciex 5500 QTrap ABI Sciex 5500 QTrap ABI Sciex 5500 QTrap
Ion Mode NEGATIVE NEGATIVE NEGATIVE NEGATIVE
Units ng/g tissue mg/mL ng/mL mg/g tissue

MS:

MS ID:MS003584
Analysis ID:AN003842
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:QTRAP
MS Type:ESI
MS Comments:Mass spectra for each detected lipid metabolite were recorded using the enhanced production feature to verify the identity of the detected peak. Data were collected and quantified using Analyst 1.6.2 (SCIEX) and MultiQuant (SCIEX) software, respectively. Correction for recovery efficiencies and relative quantitation of each analyte were performed using signals from each chromatogram corresponding to the spiked-in internal standards. Under standardized conditions of liquid chromatography-mass spectrometry quantitation, the detection limits for the eicosanoids are 1–2 pg on the column and the limit of quantitation is 5 pg at a signal-to-noise ratio of 3.
Ion Mode:NEGATIVE
  
MS ID:MS003585
Analysis ID:AN003843
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:QTRAP
MS Type:ESI
MS Comments:Mass spectra for each detected lipid metabolite were recorded using the enhanced production feature to verify the identity of the detected peak. Data were collected and quantified using Analyst 1.6.2 (SCIEX) and MultiQuant (SCIEX) software, respectively. Correction for recovery efficiencies and relative quantitation of each analyte were performed using signals from each chromatogram corresponding to the spiked-in internal standards. Under standardized conditions of liquid chromatography-mass spectrometry quantitation, the detection limits for the eicosanoids are 1–2 pg on the column and the limit of quantitation is 5 pg at a signal-to-noise ratio of 3.
Ion Mode:NEGATIVE
  
MS ID:MS003586
Analysis ID:AN003844
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:QTRAP
MS Type:ESI
MS Comments:Mass spectra for each detected lipid metabolite were recorded using the enhanced production feature to verify the identity of the detected peak. Data were collected and quantified using Analyst 1.6.2 (SCIEX) and MultiQuant (SCIEX) software, respectively. Correction for recovery efficiencies and relative quantitation of each analyte were performed using signals from each chromatogram corresponding to the spiked-in internal standards. Under standardized conditions of liquid chromatography-mass spectrometry quantitation, the detection limits for the eicosanoids are 1–2 pg on the column and the limit of quantitation is 5 pg at a signal-to-noise ratio of 3.
Ion Mode:NEGATIVE
  
MS ID:MS003587
Analysis ID:AN003845
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:QTRAP
MS Type:ESI
MS Comments:Mass spectra for each detected lipid metabolite were recorded using the enhanced production feature to verify the identity of the detected peak. Data were collected and quantified using Analyst 1.6.2 (SCIEX) and MultiQuant (SCIEX) software, respectively. Correction for recovery efficiencies and relative quantitation of each analyte were performed using signals from each chromatogram corresponding to the spiked-in internal standards. Under standardized conditions of liquid chromatography-mass spectrometry quantitation, the detection limits for the eicosanoids are 1–2 pg on the column and the limit of quantitation is 5 pg at a signal-to-noise ratio of 3.
Ion Mode:NEGATIVE