Return to study ST002399 main page

MB Sample ID: SA239072

Local Sample ID:Blank4-2
Subject ID:SU002488
Subject Type:Cultured cells
Subject Species:Mus musculus
Taxonomy ID:10090
Subject Comments:OP9 cells were left as stromal cells or were differentiated into adipocytes. These cells were allowed to condition media, with the media being the analyte in this study.

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003906
Analysis type MS
Chromatography type HILIC
Chromatography system Thermo Vanquish
Column SeQuant ZIC-HILIC (100 x 2.1mm,3.5um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE
Units Peak area

MS:

MS ID:MS003645
Analysis ID:AN003906
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Compound Discoverer 3.3 (Thermo Scientific) was used for data analysis of metabolomic experiments, including retention time alignment across runs, cubic spline normalization of areas for each metabolite in quality control pooled samples, and gap-filling based on real peak detection. The minimum peak intensity was 5x105, and metabolites were excluded if they had >50% relative standard deviation after correction or a max sample area <5-fold that of the blank. Furthermore, to be considered a high-confidence metabolite for analysis, metabolites required a) an accurate mass (5 ppm) match and either (i) retention time (±5%) matching of reference standards, and/or (ii) matching to MS2 spectra in mzCloud (mzcloud.org) (including at least one matching product ion); b) an accurate mass and retention time match to a lipid identity determined by LipidSearch (ThermoFisher, all default parameters used) based on MS2 data; and/or c) an MS2 fragment ion matching to a particular class of compounds (184.1 for phosphatidylcholine). When a chromatographic peak matched to two standards of similar retention time that were indistinguishable by MS2, we prioritized the metabolite with higher abundance in human or retained both annotations. The naming convention for the metabolites reported herein is as follows – a) if the metabolite was an accurate mass and retention time match to our curated library or to our LipidSearch library, it is listed only as the metabolite name; b) if the metabolite had an MS2 library match but no match in the aforementioned libraries, it is listed as the MS2 match and the retention time; c) if the metabolite had an MS2 compound class match, it is listed as the compound class, the chemical formula (or the molecular weight if formula was not available), and the retention time.
Ion Mode:POSITIVE
Capillary Temperature:275
Ionization Potential:+3.5 kV
Automatic Gain Control:1E6
  logo