Summary of Study ST002880

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001801. The data can be accessed directly via it's Project DOI: 10.21228/M8X43S This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002880
Study TitleHypoxia-driven dynamics of tomato root lipidome
Study SummaryA distinct, hypoxia-related lipid composition of Solanum lycopersicum root tissue was observed. Out of 965 lipid species, 33 were exclusively detected in this condition. Among the lipid classes observed, glycerolipids and glycerophospholipids dominated by far (77%). Significantly, the abundance of triacylglycerols increased with hypoxic stress, while sitosterol esters, digalactosyldiacylglycerols, and phosphatidylcholine decreased. Alongside, an increased level of polyunsaturation was observed in the fatty acid chains, with 18:2, 18:3 residues showing a significant increase. Of note, hexadecatetraenoic acid (16:4) was identified in hypoxia condition samples.
Institute
Leibniz Institute for Plasma Science and Technology
Last NameWende
First NameKristian
AddressF.-Hausdorff-Str. 2, D-17489 Greifswald
Emailkristian.wende@inp-greifswald.de
Phone+49 3834 554 3923
Submit Date2023-09-15
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2023-10-16
Release Version1
Kristian Wende Kristian Wende
https://dx.doi.org/10.21228/M8X43S
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004719 AN004720
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Thermo Accucore C30 (150 x 2.1mm,2.6um) Thermo Accucore C30 (150 x 2.1mm,2.6um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE NEGATIVE
Units normalized relative abundance normalized relative abundance (a.u.)
  logo