This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000330. The data can be accessed directly via it's Project DOI: 10.21228/M8W02Q This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files
Study IDST000443
Study TitleQuantitative measurements of TCA cycle metabolites in T1D poor control, good control, and controls.
Study TypeQuantitative measurements of plasma levels of tricarboxylic acid (TCA) cycle metabolites
Study SummaryThe objective of the study was to determine whether T1D with good glycemic control have persistent abnormalities of metabolites and pathways that exist in T1D with poor glycemic control.
Institute
Mayo Clinic
DepartmentEndocrinology
LaboratoryMayo Clinic Metabolomics Resource Core
Last NameNair
First NameSreekumaran
Address200 First Street SW, Rochester, MN 55905
EmailNair.K@mayo.edu
Phone507-285-2415
Submit Date2016-07-20
Raw Data File Type(s)d
Analysis Type DetailGC-MS
Release Date2016-09-23
Release Version1
Sreekumaran Nair Sreekumaran Nair
https://dx.doi.org/10.21228/M8W02Q
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000694
Analysis type MS
Chromatography type GC
Chromatography system Agilent 6890
Column None
MS Type EI
MS instrument type Single quadrupole
MS instrument name Agilent 5973
Ion Mode POSITIVE
Units micromolar

Chromatography:

Chromatography ID:CH000502
Chromatography Summary:The derivatized extracts were analyzed with an Agilent 6890 gas chromatograph coupled with an Agilent 5973 mass selective detector. The 1-μL aliquots of the extracts were injected into a DB5-MS capillary column (30 m × 250 μm i.d., 0.25-μm film thickness; J&W Scientific, Folson, CA) using PTV injection (Gerstel CIS4 injector) in the splitless mode. The temperature of the PTV was 70 °C during injection, and 0.6 min after injection, the temperature was raised to 300 °C at a rate of 2 °C/s and held at 300 °C for 20 min. The initial GC oven temperature was 70 °C, 5 min after injection the GC oven temperature was increased with 5 °C/min to 320 °C and held for 5 min at 320 °C. Helium was used as a carrier gas and pressure programmed such that the helium flow was kept constant at a flow rate of 1.7 mL/min. Detection was achieved using MS detection in electron impact mode and full scan monitoring mode (m/z 15−800). The temperature of the ion source was set at 250 °C and that of the quadrupole at 200 °C.
Instrument Name:Agilent 6890
Column Name:None
Chromatography Type:GC