Summary of Study ST000966

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000663. The data can be accessed directly via it's Project DOI: 10.21228/M8ZX0W This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)
Study IDST000966
Study TitleMetabolite and gene expression profiles suggest a putative mechanism through which high dietary carbohydrates reduce the content of hepatic betaine in Megalobrama amblycephala
Study Summaryplasma of Megalobrama amblycephala fed with control diet, high carbohydrates diet,betaine diet with 16 weeks and betaine diet with 4 weeks.
Institute
College of Fisheries Huazhong Agricultural University
Last NameXu
First NameJia
Address1 Shizishan Road Hongshan District Wuhan
Emailxujia2018hzau@163.com
Phone13018097215
Submit Date2018-05-04
Analysis Type DetailLC-MS
Release Date2018-06-05
Release Version1
Jia Xu Jia Xu
https://dx.doi.org/10.21228/M8ZX0W
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001580
Analysis type MS
Chromatography type Reversed phase
Chromatography system Unspecified
Column Unspecified
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name
Ion Mode POSITIVE
Units ng/ml or umol/L

Chromatography:

Chromatography ID:CH001109
Chromatography Summary:The HPLC system consisted of a SRD-3600 Solvent Rack with analytical 6-channel vacuum degasser, a DGP-3600A pump, WPS-3000TSL analytical autosampler, and a tcc-3200 column compartment. Chromatographic separations were performed on an MSLab C18 column (150×4.6mm, 5μm). The mobile phase A was 0.1% formic acid in water, and the organic mobile phase B was 0.1% ammonium formate in acetonitrile with pH=5.8. The solvent was delivered to the column at a flow rate of 1 ml min−1 as follows: 0-1 minutes from A-B (90:10) to A-B (90:10); 1-12 minutes from A-B (90:10) to A-B (30:70); 12-12.1 minutes from A-B (30:70) to A-B (0:100); 12.1-15 minutes from A-B (0:100) to A-B (0:100); 15-15.1 minutes from A-B (0:100) to A-B (90:10); 15.1-20 minutes from A-B(90:10) to A-B (90:10).
Instrument Name:Unspecified
Column Name:Unspecified
Flow Gradient:0-1 minutes from A-B (90:10) to A-B (90:10); 1-12 minutes from A-B (90:10) to A-B (30:70); 12-12.1 minutes from A-B (30:70) to A-B (0:100); 12.1-15 minutes from A-B (0:100) to A-B (0:100); 15-15.1 minutes from A-B (0:100) to A-B (90:10); 15.1-20 minutes from A-B(90:10) to A-B (90:10).
Flow Rate:1ml/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% ammonium formate, pH 5.8
Chromatography Type:Reversed phase
  logo