Summary of Study ST001432
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000983. The data can be accessed directly via it's Project DOI: 10.21228/M8N104 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST001432 |
Study Title | A Compromised Developmental Trajectory of the Infant Gut Microbiome and Metabolome in Atopic Eczema - (untargeted global metabolomics profiling) ) |
Study Summary | Evidence is accumulating that the establishment of the gut microbiome in early life influences the development of atopic eczema. In this longitudinal study, we used integrated multi-omics analyses to infer functional mechanisms by which the microbiome modulates atopic eczema risk. |
Institute | National University of Singapore |
Last Name | Ta |
First Name | Le Duc Huy |
Address | MD1 - Tahir Foundation Building (MD1), Level 15, Department of Paediatrics, Allergy & Immunology Division, National University of Singapore (NUS), 12 Science Drive 2. Singapore 117549 |
huy.taleduc13@sps.nus.edu.sg | |
Phone | 6596123681 |
Submit Date | 2020-05-28 |
Num Groups | 3 |
Total Subjects | 63 |
Raw Data Available | Yes |
Raw Data File Type(s) | peg |
Analysis Type Detail | GC-MS |
Release Date | 2020-07-24 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002394 |
---|---|
Analysis type | MS |
Chromatography type | GC |
Chromatography system | Agilent 7890A |
Column | Agilent DB-1 DB-1 (30 m × 250 um i.d.) |
MS Type | EI |
MS instrument type | GC-TOF |
MS instrument name | Leco Pegasus III GC TOF |
Ion Mode | POSITIVE |
Units | Ion Count Per Second |
Chromatography:
Chromatography ID: | CH001760 |
Chromatography Summary: | Helium was employed as the carrier gas at a constant flow rate of 1.5 mL/min and the injector split ratio was adjusted to 1:10. An injection volume of 1 µL was used. The injector, transfer line and ionsource temperatures were maintained at 220, 280 and 250°C, respectively. The oven temperature was programmed at 70°C for 0.2 min, increased at 9°C/min to 270°C where it was sustained for 5 min, and further increased at 40°C/min to 310°C where it was held for 11 min. The mass spectrometer was operated in the electron impact ionization mode at 70 eV. Data were acquired in full scan mode from m/z 40 to 600 with an acquisition rate of 20 spectra per second. To detect retention time shifts and facilitate Kovats retention index (RI) calculation, a standard alkane series mixture (C7-C30) was injected before every batch during sample analysis. This was accompanied by an injection of one pooled QC after every injection of 10 samples. |
Instrument Name: | Agilent 7890A |
Column Name: | Agilent DB-1 DB-1 (30 m × 250 um i.d.) |
Chromatography Type: | GC |