Summary of Study ST001675

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001078. The data can be accessed directly via it's Project DOI: 10.21228/M8C111 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001675
Study TitleQuantitative measurements of ceramides and glycosphingolipids in Th17 and iTreg cells (part-II)
Study TypeMS: Targeted analysis
Study SummaryPart 2/5: It includes quantitative targeted measurements of sphingolipids (ceramides and glycosphingolipids) in Th17, iTreg, and their paired controls (Th0 cells).
Institute
University of Turku
DepartmentSystems Medicine, Turku Bioscience
LaboratoryMetabolomics
Last NameSen
First NamePartho
AddressTykistökatu 6B, BioCity, 5th Floor
Emailpartho.sen@utu.fi
Phone0469608145
Submit Date2021-01-31
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2021-11-02
Release Version1
Partho Sen Partho Sen
https://dx.doi.org/10.21228/M8C111
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002733
Analysis type MS
Chromatography type Reversed phase
Chromatography system Waters Acquity UHPLC UNSPSC 41115709
Column Waters BEH C18 (00mm x 2.1mm,1.7um )
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name ABI Sciex 5500 QTrap
Ion Mode POSITIVE
Units ng/ml

Chromatography:

Chromatography ID:CH002019
Chromatography Summary:Chromatographic separation was performed on an ACQUITY UHPLC BEH C18 column (2.1 mm × 100 mm, particle size 1.7 µm, Waters, Milford, MA, USA). The flow rate was set at 0.4 ml/min throughout the run with an injection volume of 1 µL. The following solvents were used for the gradient elution: Solvent A was H2O with 1% NH4Ac (1M) and HCOOH (0.1%) added. Solvent B was a mixture of ACN: IPA (1:1 v/v) with 1% NH4Ac (1M) and HCOOH (0.1%) added. The gradient was programmed as follows: 0 to 2 min 35-80% B, 2 to 7 min 80-100 % B, 7 to 14 min 100% B. The column was equilibrated with a 7min period of 35 % B prior to the next run.
Instrument Name:Waters Acquity UHPLC UNSPSC 41115709
Column Name:Waters BEH C18 (00mm x 2.1mm,1.7um )
Flow Gradient:The gradient was programmed as follows: 0 to 2 min 35-80% B, 2 to 7 min 80-100 % B, 7 to 14 min 100% B. The column was equilibrated with a 7min period of 35 % B prior to the next run.
Flow Rate:0.4ml/min
Solvent A:100% water; 0.1% formic acid; 1% ammonium acetate
Solvent B:50% acetonitrile/50% isopropanol; 0.1% formic acid; 1% ammonium acetate
Chromatography Type:Reversed phase