Summary of Study ST002043

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001290. The data can be accessed directly via it's Project DOI: 10.21228/M8ZQ4B This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002043
Study TitleMaternal Hypoxemia and Oxidative Stress
Study Typeuntargeted metabolomics
Study SummaryThis project seeks to understand the metabolic consequences of gestational hypoxia on fetal, newborn, and adult plasma, arteries and other tissues using a sheep model of fetal growth restriction. Specifically we are interested testing the hypothesis that gestational hypoxia will result in discernable differences in glucose and lipid metabolism in tissues and plasma as well influence indicators of oxidative stress and inflammation. These studies aim to delineate pathways and biomarkers that help explain how hypoxia leads to the development of neonatal as well as adult-onset diseases associated with chronic hypoxia that are inter-related with fetal growth restriction. From a vascular perspective this includes cerebrovascular hemorrhage and pulmonary hypertension in the newborn, but more broadly it includes development of diseases later in life including diabetes, hypertension, and coronary artery disease.
Institute
Loma Linda University School of Medicine
DepartmentLawrence D. Longo, MD Center for Perinatal Biology
LaboratorySean Wilson, Center for Perinatal Biology
Last NameWilson
First NameSean
Address11234 Anderson Street, MC A582, Loma Linda, California 92350
Emailseanwilson@llu.edu
Phone909-558-4325
Submit Date2021-12-01
Raw Data AvailableYes
Raw Data File Type(s)cdf
Analysis Type DetailGC-MS
Release Date2022-01-21
Release Version1
Sean Wilson Sean Wilson
https://dx.doi.org/10.21228/M8ZQ4B
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003324
Analysis type MS
Chromatography type GC
Chromatography system Leco Pegasus IV GC
Column Restek Rtx-5Sil (30m x 0.25mm,0.25um)
MS Type EI
MS instrument type QTOF
MS instrument name Leco Pegasus IV TOF
Ion Mode UNSPECIFIED
Units normalized peak height

Chromatography:

Chromatography ID:CH002463
Chromatography Summary:GC-TOF Method: Instruments: Gerstel CIS4 –with dual MPS Injector/ Agilent 6890 GC- Pegasus III TOF MS Injector conditions: Agilent 6890 GC is equipped with a Gerstel automatic liner exchange system (ALEX) that includes a multipurpose sample (MPS2) dual rail, and a Gerstel CIS cold injection system (Gerstel, Muehlheim, Germany) with temperature program as follows: 50°C to 275°C final temperature at a rate of 12 °C/s and hold for 3 minutes. Injection volume is 0.5 μl with 10 μl/s injection speed on a splitless injector with purge time of 25 seconds. Liner (Gerstel #011711-010-00) is changed after every 10 samples, (using the Maestro1 Gerstel software vs. 1.1.4.18). Before and after each injection, the 10 μl injection syringe is washed three times with 10 μl ethyl acetate. Gas Chromatography conditions: A 30 m long, 0.25 mm i.d. Rtx-5Sil MS column (0.25 μm 95% dimethyl 5% diphenyl polysiloxane film) with additional 10 m integrated guard column is used (Restek, Bellefonte PA). 99.9999% pure Helium with built-in purifier (Airgas, Radnor PA) is set at constant flow of 1 ml/min. The oven temperature is held constant at 50°C for 1 min and then ramped at 20°C/min to 330°C at which it is held constant for 5 min.
Instrument Name:Leco Pegasus IV GC
Column Name:Restek Rtx-5Sil (30m x 0.25mm,0.25um)
Chromatography Type:GC
  logo