Summary of Study ST002351

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001510. The data can be accessed directly via it's Project DOI: 10.21228/M8HD93 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002351
Study TitleCharacterizing the intrauterine environment via untargeted metabolomics profiling of maternal blood collected during pregnancy (Atlanta ECHO Cohort)
Study TypeProspective Cohort Study
Study SummaryThe Atlanta ECHO Cohort is comprised of African American mother-child dyads who reside in the greater metropolitan Atlanta area. Enrollment begins during pregnancy from prenatal care clinics affiliated with two metro hospital systems. During pregnancy, data and biospecimens are obtained during an initial study visit (between 8-14 weeks gestation) and during a second study visit (between 24-30 weeks gestation). In the perinatal period, we collect the residual newborn blood spot (obtained from the neonate during the delivery hospitalization for state metabolic screening). Details of pregnancy complications, birth, and neonatal outcomes are ascertained via medical record abstraction. Children are then followed annually via in-person clinical assessments and maternal questionnaire data. This research was supported by the Environmental influences on Child Health Outcomes (ECHO) program, Office of The Director, National Institutes of Health. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. The Atlanta ECHO Cohort is supported by the following ECHO Program Collaborators: ECHO Coordinating Center: Duke Clinical Research Institute, Durham, North Carolina: Smith PB, Newby KL, Benjamin DK; U2C OD023375 ECHO Data Analysis Center: Johns Hopkins University Bloomberg School of Public Health, Baltimore, Maryland: Jacobson LP; Research Triangle Institute, Durham, North Carolina: Catellier D; U24 OD023382 North Carolina Human Health Exposure Analysis Resource Hub: Research Triangle Institute: Fennell T, University of North Carolina at Chapel Hill: Sumner S, University of North Carolina at Charlotte: Du X; U2C ES030857 Human Health Exposure Analysis Resource Coordinating Center: Westat, Inc., Rockville, Maryland: O’Brien B; U24 ES026539
Institute
Emory University
DepartmentSchool of Medicine, Department of Gynecology & Obstetrics; School of Public Health, Department of Environmental Health
Last NameDunlop
First NameAnne
Address101 Woodruff Circle, Rm 4303 Woodruff Memorial Building, Atlanta, GA 30322
Emailamlang@emory.edu
Phone(404) 712-8520
Submit Date2022-11-14
Total Subjects564
Study CommentsHHEAR Project EM19-0009, ECHO Project EC0374
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2023-11-14
Release Version1
Anne Dunlop Anne Dunlop
https://dx.doi.org/10.21228/M8HD93
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003837
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Scientific™ Vanquish™ UPHPLC
Column Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,3um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive HF-X Orbitrap
Ion Mode POSITIVE
Units Normalized intensity

Chromatography:

Chromatography ID:CH002841
Instrument Name:Thermo Scientific™ Vanquish™ UPHPLC
Column Name:Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,3um)
Column Pressure:6000-10000 psi
Column Temperature:50
Flow Gradient:Time(min) Flow Rate %A %B Curve 1. 0 0.4 99.0 1.0 5 2. 1.00 0.4 99.0 1.0 5 3. 16.00 0.4 1.0 99.0 5 4. 19.00 0.4 1.0 99.0 5 5. 19.50 0.4 99.0 1.0 5 6. 22.00 0.4 99.0 1.0 5
Flow Rate:0.4 ml/min
Injection Temperature:8
Solvent A:100% water; 0.1% formic acid
Solvent B:100% methanol; 0.1% formic acid
Randomization Order:Randomized
Chromatography Type:Reversed phase
  logo