Summary of Study ST002485
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001607. The data can be accessed directly via it's Project DOI: 10.21228/M8013C This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002485 |
Study Title | Simultaneous targeting of PD-1 and IL2Rβγ with radiation therapy to inhibit pancreatic cancer growth and metastasis - mouse serum metabolomics |
Study Summary | Mice were orthotopically implanted with PK5L1940 cells then radiation therapy (8 Gy) administered 7 days post-implantation. PD1-IL2v and aCD25 dosed once per week beginning day 7 post-implantation. Serum was collected at time of sacrifice and profiled by mass spectrometry-based metabolomics to visualize changes in systemic metabolism in the mouse model. |
Institute | University of Colorado Denver |
Last Name | Haines |
First Name | Julie |
Address | 12801 E 17th Ave, Room 1303, Aurora, Colorado, 80045, USA |
julie.haines@cuanschutz.edu | |
Phone | 3037243339 |
Submit Date | 2023-02-21 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2023-03-10 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004056 | AN004057 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Phenomenex Kinetex C18 2.1 x 150 mm, 1.7 um | Phenomenex Kinetex C18 2.1 x 150 mm, 1.7 um |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | NEGATIVE | POSITIVE |
Units | peak area | peak area |
Chromatography:
Chromatography ID: | CH003002 |
Chromatography Summary: | Negative C18 |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 2.1 x 150 mm, 1.7 um |
Column Temperature: | 45 |
Flow Gradient: | 0-0.5 min 0% B, 0.5-1.1 min 0-100% B, 1.1-2.75 min hold at 100% B, 2.75-3 min 100-0% B, 3-5 min hold at 0% B |
Flow Rate: | 450 uL/min |
Sample Injection: | 10 uL |
Solvent A: | 95% water 5% acetonitrile 1 mM ammonium acetate |
Solvent B: | 95% acetonitrile 5% water 1 mM ammonium acetate |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH003003 |
Chromatography Summary: | Positive C18 |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 2.1 x 150 mm, 1.7 um |
Column Temperature: | 45 |
Flow Gradient: | 0-0.5 min 5% B, 0.5-1.1 min 5-95% B, 1.1-2.75 min hold at 95% B, 2.75-3 min 95-5% B, 3-5 min hold at 5% B |
Flow Rate: | 450 uL/min |
Sample Injection: | 10 uL |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100%acetonitrile; 0.1% formic acid |