Summary of Study ST003172

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001972. The data can be accessed directly via it's Project DOI: 10.21228/M8TJ0V This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003172
Study TitleUntargeted Metabolomic Profile Of Chili Pepper (Capsicum Chinensed) Developmental Cycle
Study SummaryTo explore the temporal dynamics of metabolites in chili peppers at various developmental stages, we employed a non-targeted metabolomics method based on liquid chromatography-mass spectrometry (LC-MS). The metabolome data collection began on the day of flowering (0 days post-anthesis), and continued for 7, 16, 30, 50, 55, and 60 DPA. This comprehensive dataset paved the way for future studies on metabolite changes and biological processes in chili peppers throughout their life cycle.
Institute
University of Alberta
DepartmentDepartment of Chemistry
Last NameYang
First NameBowen
Address11227 Saskatchewan Drive
, Edmonton, Alberta, Canada T6G 2G2
Emailby8@ualberta.ca
Phone8259758666
Submit Date2024-04-13
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2024-04-18
Release Version1
Bowen Yang Bowen Yang
https://dx.doi.org/10.21228/M8TJ0V
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005206
Analysis type MS
Chromatography type Reversed phase
Chromatography system Waters Acquity H-Class
Column Waters ACQUITY UPLC HSS T3 (150 x 2.1mm, 1.8um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Orbitrap Exploris™ 240 Mass Spectrometer
Ion Mode UNSPECIFIED
Units peak area

Chromatography:

Chromatography ID:CH003939
Chromatography Summary:Metabolic profiling data from chili peppers (Capsicum chinese L.) was collected. Pepper seedlings were grown in a greenhouse of Peking University Institute of Advanced Agricultural Sciences with a controlled environment of 25°C temperature, a light-dark cycle of 16 hours light and 8 hours dark, and 70% relative humidity. The fruits of peppers were sampled at seven distinct time points, starting from the day of flowering, i.e. 0 day post-anthesis (DPA) during which flowers were collected. Following this, fruits were harvested on days 7, 16, 30, 50, 55, and 60 DPA. The samples were ground and freeze-dried in liquid nitrogen, followed by extraction using 1.0 mL of 70% aqueous methanol for every 50 mg of the sample, and an ultrasonic process was employed for 30 minutes. The preparation of standards was conducted as follows: a mixed standard in the range of 20-50μg/mL was prepared using methanol of MS grade. For the amino acid standard solution, a 1mg/mL stock solution was prepared in water and subsequently diluted with 50% methanol to achieve a concentration of 50μg/mL. Three biological replicates were used metabolome analysis. The metabolome profiling was carried out using untargeted metabolomics based on liquid chromatography coupled with mass spectrometry (LC-MS). The samples were filtered through a 0.22 µm membrane and transferred into the lining tube of a sampling vial. Subsequent centrifugation was carried out at 12000 rcf and 4°C for 10 minutes. The processed samples were then analyzed using Thermo Scientific Orbitrap Exploris™ 240 (Thermo Fisher Scientific, USA). Chromatographic separation was achieved on a T3 C18 (1.7 µm, 2.1 mm × 150 mm column, USA) maintained at 40°C. The mobile phase consisted of A: 1% formic acid in water and B: 1% formic acid in acetonitrile, with a flow rate of 300 µL/min. A 3 µL sample was injected at an autosampler temperature of 10°C. The elution gradient was set as follows: 0-2.5 min, 3-10% B; 2.5-6 min, 10-44% B; 6-14 min, 44-80% B; 14-20 min, 80-95% B; 20-23 min, 95% B; 23-23.1 min, 95-3% B; 23.1-28 min, 3% B. MS was performed using both positive and negative ion scans, with a precursor ion scan mode. The auxiliary gas heater temperature was set at 350°C, and the ion transfer tube temperature was also maintained at 350°C. The sheath gas flow rate and auxiliary gas flow rate were set to 35 arb and 15 arb, respectively. The voltages were set to 3.5 KV for the positive spectrum and 3.2 KV for the negative spectrum. For MS1, the scan resolution was 60000, with a scan range of 80-1200. For MS2, the scan resolution was 15000, with a stepped collision energy of 20, 40, and 60 eV. Metabolite identification and quantification were performed using the Compound Discoverer software 3.3 (Thermo Fisher Scientific, USA).
Instrument Name:Waters Acquity H-Class
Column Name:Waters ACQUITY UPLC HSS T3 (150 x 2.1mm, 1.8um)
Column Temperature:40℃
Flow Gradient:0-2.5 min,3-10% B;2.5-6 min,10-44% B;6-14 min,44-80% B;14-20 min,80-95% B;20-23 min,95% B;23-23.1 min,95-3% B;23.1-28 min,3% B
Flow Rate:300 μL/min
Solvent A:100% Water; 1% Formic Acid
Solvent B:100% Acetonitrile; 1% Formic Acid
Chromatography Type:Reversed phase
  logo