Summary of Study ST001926
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001216. The data can be accessed directly via it's Project DOI: 10.21228/M8J11K This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001926 |
Study Title | Modular evolution of the Drosophila metabolome |
Study Summary | In this study, we look at both targeted and untargeted metabolomic data from both sexes and 11 species of Drosophila. For the targeted analysis, we also looked at two ages to understand conserved changes with age in the Drosophila genus. |
Institute | University of Washington |
Last Name | Promislow |
First Name | Daniel |
Address | 1959 NE Pacific Street, Seattle, Washington, 98195, USA |
promislo@uw.edu | |
Phone | 206-616-6994 |
Submit Date | 2021-09-01 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzXML |
Analysis Type Detail | LC-MS |
Release Date | 2022-02-02 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003130 | AN003131 | AN003132 |
---|---|---|---|
Analysis type | MS | MS | MS |
Chromatography type | HILIC | HILIC | HILIC |
Chromatography system | Agilent 1260 | Agilent 1260 | Agilent 1260 |
Column | Waters Xbridge BEH HILIC (75 x 2.1mm,2.5um) | Waters Xbridge BEH HILIC (75 x 2.1mm,2.5um) | Waters Xbridge BEH HILIC (75 x 2.1mm,2.5um) |
MS Type | ESI | ESI | ESI |
MS instrument type | Triple quadrupole | QTOF | QTOF |
MS instrument name | ABI Sciex 5500 QTrap | Agilent 6520 QTOF | Agilent 6520 QTOF |
Ion Mode | UNSPECIFIED | POSITIVE | NEGATIVE |
Units | Peak counts | Peak counts |
MS:
MS ID: | MS002910 |
Analysis ID: | AN003130 |
Instrument Name: | ABI Sciex 5500 QTrap |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Targeted data acquisition was performed in multiple-reaction-monitoring (MRM) mode. The LC-MS system was controlled by Analyst 1.5 software (AB Sciex). The extracted MRM peaks were integrated using MultiQuant 2.1 software (AB Sciex). Both positive and negative ionization modes were used. |
Ion Mode: | UNSPECIFIED |
MS ID: | MS002911 |
Analysis ID: | AN003131 |
Instrument Name: | Agilent 6520 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | The ESI voltage was 3.8 kV, and the m/z scan range was 60-1000. The Q-TOF data were extracted using Agilent MassHunter Qualitative Analysis (version B.07.00), Quantitative Analysis (version B.07.01), and Mass Profiler Professional (MPP, version B.13.00) software. The absolute intensity threshold for the LC-Q-TOF data extraction was 1000, and the mass accuracy limit was set to 10 ppm. Both positive and negative ionization modes were analyzed. |
Ion Mode: | POSITIVE |
MS ID: | MS002912 |
Analysis ID: | AN003132 |
Instrument Name: | Agilent 6520 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | The ESI voltage was 3.8 kV, and the m/z scan range was 60-1000. The Q-TOF data were extracted using Agilent MassHunter Qualitative Analysis (version B.07.00), Quantitative Analysis (version B.07.01), and Mass Profiler Professional (MPP, version B.13.00) software. The absolute intensity threshold for the LC-Q-TOF data extraction was 1000, and the mass accuracy limit was set to 10 ppm. Both positive and negative ionization modes were analyzed. |
Ion Mode: | NEGATIVE |