Summary of Study ST002029

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001287. The data can be accessed directly via it's Project DOI: 10.21228/M8BX22 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002029
Study TitleMetabolomics Analysis of Blood Plasma and Stool from Six Week Flaxseed Dietary Intervention in Postmenopausal Women (Serum/Bile acids)
Study SummarySamples were taken before and after 6 weeks of flaxseed dietary intervention. Serum and fecal metabolomics were performed to characterize the metabolomic profiles of serum and stool metabolites pre- and post-intervention.
Institute
University of California, Davis
Last Namefolz
First Namejake
Address451 Health Science Drive
Emailjfolz@ucdavis.edu
Phone7155636311
Submit Date2021-12-21
Raw Data AvailableYes
Raw Data File Type(s)wiff
Analysis Type DetailLC-MS
Release Date2023-01-02
Release Version1
jake folz jake folz
https://dx.doi.org/10.21228/M8BX22
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003299
Analysis type MS
Chromatography type Reversed phase
Chromatography system Vanquish
Column Waters Acquity BEH C18 (100 x 2mm,1.7um)
MS Type ESI
MS instrument type Ion trap
MS instrument name ABI Sciex 6500+
Ion Mode NEGATIVE
Units nM

MS:

MS ID:MS003069
Analysis ID:AN003299
Instrument Name:ABI Sciex 6500+
Instrument Type:Ion trap
MS Type:ESI
MS Comments:Extracts were analyzed by liquid chromatography (Waters ACQUITY UPLC I-Class system) coupled to a Sciex 6500+ QTRAP hybrid, triple quadrupole linear ion trap mass spectrometer. 5 µL of each extract was injected. Scheduled multiple reaction monitoring (MRM) was performed with optimized collision energies, de-clustering potentials, and collision cell exit potentials for individual analyte. A LC-MRM targeted method was used to analyze both bile acids and steroids with positive and negative polarity switching. Oxylipins were analyzed in another LC-MRM method in negative ionization mode only. All analytes were quantified against 6-point calibration curves using internal standards. Turbo Spray Ion Source parameters are: curtain gas (CUR) 25 psi, nebulizer gas (GS1) 50 psi, turbo-gas (GS2) 50 psi, electrospray voltage −4.5 kV/+3 kV, and source temperature 525 ◦C. Nitrogen was used as the collision gas. Software Analyst 1.6.3 and MultiQuant 3.0.2 (AB Sciex) were used for data acquisition and quantification. MRM transitions for the analytes are provided in the supplementary Tables S8 and S9.
Ion Mode:NEGATIVE
  logo