Summary of Study ST002243

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001432. The data can be accessed directly via it's Project DOI: 10.21228/M8MQ5M This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002243
Study TitleLipidomics analysis of Friedreich's ataxia (FRDA) (part II)
Study TypeUntargeted and targeted (PRM) analysis
Study SummaryFriedreich’s Ataxia (FRDA) is an autosomal neurodegenerative disease caused by the deficiency of protein frataxin. Frataxin functions in the assembly of iron-sulfur clusters that are important for iron homeostasis and metabolic functions. To identify metabolic features that can be used for potential biomarkers in FRDA plasma, we performed a targeted multi-omics (metabolomics, lipidomics, and proteomics) analysis using discovery-validation cohort design. Muti-omics analysis revealed that FRDA patients had dysregulated sphingolipid metabolism, phospholipid metabolism, citric acid cycle, amino acid metabolism, and apolipoprotein metabolism. Sphingolipid dysfunctions were revealed by decreased very long chain ceramides but unchanged long chain ceramides in FRDA plasma, which resulted in the increased ratio of long chain ceramides to very long chain ceramides. Decreased very long chain ceramides distinguished FRDA patients from healthy controls and showed good predictive capacities with AUC values from 0.75 to 0.85. Furthermore, by performing lipidomic and stable isotope tracing experiment in induced pluripotent stem cell differentiated cardiomyocytes (iPSC-CMs, we demonstrated that frataxin deficiency affected ceramide synthase (CerS2), and preferentially enriched long chain ceramides and depleted very long chain ceramides. Moreover, ceramide metabolism was differentially regulated in a tissue-specific manner. Finally, machine learning model increased the prediction of FRDA using the combination of three metabolites (AUC > 0.9). In conclusion, decreased very long chain ceramides are potential biomarkers and therapeutic target in FRDA patients.
Institute
University of Pennsylvania
Last NameWang
First NameDezhen
Address421 Curie Blvd, Philadelphia, PA, 19104, USA
Emaildezhen.wang@pennmedicine.upenn.edu
Phone5312185610
Submit Date2022-07-29
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2022-08-22
Release Version1
Dezhen Wang Dezhen Wang
https://dx.doi.org/10.21228/M8MQ5M
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003661 AN003662
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Thermo Accucore C18 (100 x 2.1mm,2.6um) Thermo Accucore C18 (100 x 2.1mm,2.6um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units intensity intensity

MS:

MS ID:MS003412
Analysis ID:AN003661
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Samples were analyzed using a Q Exactive HF (QE-HF) (Thermo Scientific, Waltham, MA) equipped with a heated electro-spray ionization (HESI) source operated in both positive and negative ion mode. For DDA library generation (untargeted lipidomics), data acquisition was performed on the pooled QC samples in Full Scan/ddMS2 mode @ 120,000 resolutions. The Full Scan settings as follows: AGC target = 1e6; Maximum IT = 250 ms; scan range = 250 to 1800 m/z. Top 20 MS/MS spectral (dd-MS2) @ 15000 were generated with AGC target = 1e5, Maximum IT=25 ms, and (N)CE/stepped nce = 20, 30, 40v. For untargeted lipid analysis, LipidSearch 4.2 (Thermo Scientific, Waltham, MA) was used for peak detection, identification, alignment, and quantification. Well annotated lipids (MS spectral match) were used to generate a inclusion list (Supplementary Table 4) for targeted lipidomics analysis. Targeted lipidomics were performed in Full scan + PRM modes. The PRM settings were as follows: resolution = 15000, AGC target = 2e5, Maximum IT=25 ms, loop count = 36, isolation window = 2.0, (N)CE was optimized for each lipid class.
Ion Mode:POSITIVE
  
MS ID:MS003413
Analysis ID:AN003662
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Samples were analyzed using a Q Exactive HF (QE-HF) (Thermo Scientific, Waltham, MA) equipped with a heated electro-spray ionization (HESI) source operated in both positive and negative ion mode. For DDA library generation (untargeted lipidomics), data acquisition was performed on the pooled QC samples in Full Scan/ddMS2 mode @ 120,000 resolutions. The Full Scan settings as follows: AGC target = 1e6; Maximum IT = 250 ms; scan range = 250 to 1800 m/z. Top 20 MS/MS spectral (dd-MS2) @ 15000 were generated with AGC target = 1e5, Maximum IT=25 ms, and (N)CE/stepped nce = 20, 30, 40v. For untargeted lipid analysis, LipidSearch 4.2 (Thermo Scientific, Waltham, MA) was used for peak detection, identification, alignment, and quantification. Well annotated lipids (MS spectral match) were used to generate a inclusion list (Supplementary Table 4) for targeted lipidomics analysis. Targeted lipidomics were performed in Full scan + PRM modes. The PRM settings were as follows: resolution = 15000, AGC target = 2e5, Maximum IT=25 ms, loop count = 36, isolation window = 2.0, (N)CE was optimized for each lipid class.
Ion Mode:NEGATIVE
  logo