Summary of Study ST002375

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001528. The data can be accessed directly via it's Project DOI: 10.21228/M8612V This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002375
Study TitleMetabolomics analysis of WT or GOT1 knockout CD8+ T cells cultured in serine-replete or serine-free media
Study SummaryWT or GOT1 knockout CD8+ T cells were activated with plate-bound anti-CD3 or soluble anti-CD28, in serine-replete or serine-free media for 24 hours. Intracellular metabolome were assessed by MS.
Institute
Johns Hopkins University
Last NameXu
First NameWei
Address1650 Orleans Street, Baltimore, MD 21287, USA.
Emailwxu29@jhmi.edu
Phone443-220-9936
Submit Date2022-11-30
Raw Data AvailableYes
Raw Data File Type(s)wiff
Analysis Type DetailLC-MS
Release Date2023-11-28
Release Version1
Wei Xu Wei Xu
https://dx.doi.org/10.21228/M8612V
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003870
Analysis type MS
Chromatography type HILIC
Chromatography system Shimadzu Prominence UFLC
Column Waters XBridge BEH Amide XP HILIC (150 x 2.1mm,2.5um)
MS Type ESI
MS instrument type QTRAP
MS instrument name ABI Sciex 5500 QTrap
Ion Mode UNSPECIFIED
Units AUC

MS:

MS ID:MS003611
Analysis ID:AN003870
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:QTRAP
MS Type:ESI
MS Comments:The optimized MS parameters were: ESI voltage was +5,000 V in positive ion mode and -4,500 V in negative ion mode; dwell time was 3 ms per SRM transition and the total cycle time was 1.57 seconds. Peak integration for each targeted metabolite in SRM transition was processed with MultiQuant software (v2.1, AB Sciex). The preprocessed data with integrated peak areas were exported from MultiQuant and re-imported into Metaboanalyst software for further data analysis (statistical analysis, principal component analysis, generating heatmap, enrichment analysis, etc.).
Ion Mode:UNSPECIFIED
  logo