Summary of Study ST002490

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001607. The data can be accessed directly via it's Project DOI: 10.21228/M8013C This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002490
Study TitleSimultaneous targeting of PD-1 and IL2Rβγ with radiation therapy to inhibit pancreatic cancer growth and metastasis - human plasma metabolomics
Study SummaryPatient plasma samples were collected as part of a Phase I radiation dose-escalation clinical trial (NCT02873598) before, during (6 hours post), and post (6 weeks) SBRT. Samples were collected and analyzed per COMIRB19–0328 for branched chain amino acids and kynurenine.
Institute
University of Colorado Denver
Last NameHaines
First NameJulie
Address12801 E 17th Ave, Room 1303, Aurora, Colorado, 80045, USA
Emailjulie.haines@cuanschutz.edu
Phone3037243339
Submit Date2023-02-21
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2023-03-10
Release Version1
Julie Haines Julie Haines
https://dx.doi.org/10.21228/M8013C
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004064
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Phenomenex Kinetex C18 2.1 x 150 mm, 1.7 um
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units peak area

MS:

MS ID:MS003811
Analysis ID:AN004064
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Resolution 70,000, scan range 65-900 m/z, maximum injection time 200 ms, microscans 2, automatic gain control (AGC) 3 x 10^6 ions, source voltage 4.0 kV, capillary temperature 320 C, and sheath gas 45, auxiliary gas 15, and sweep gas 0 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database.
Ion Mode:POSITIVE
  logo