This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001705. The data can be accessed directly via it's Project DOI: 10.21228/M89T4G This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002740
Study TitleNon-targeted metabolomics screen comparing 13C2-acetate labeling of metabolites in CD8+ T cells and NK cells from mouse spleens.
Study SummaryNon-targeted metabolomics screen comparing 13C2-acetate labeling of metabolites in CD8+ T cells and NK cells from mouse spleens (wild type vs ACSS2 knockout C57Bl/6 mice). Metabolites were analyzed using a high-resolution, high-performance LC-MS analysis.
Institute
The Wistar Institute
Last NameSchug
First NameZachary
Address3601 Spruce St, Philadelphia PA 19104
Emailzschug@wistar.org
Phone215-898-3705
Submit Date2023-06-20
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2023-07-11
Release Version1
Zachary Schug Zachary Schug
https://dx.doi.org/10.21228/M89T4G
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004443
Analysis type MS
Chromatography type HILIC
Chromatography system Thermo Vanquish
Column SeQuant ZIC-pHILIC (150 x 2.1mm, 5um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive HF-X Orbitrap
Ion Mode UNSPECIFIED
Units Peak Area

MS:

MS ID:MS004190
Analysis ID:AN004443
Instrument Name:Thermo Q Exactive HF-X Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The following parameters were used for the MS analysis: sheath gas flow rate, 30; auxiliary gas flow rate, 5; sweep gas flow rate, 0; auxiliary gas heater temperature, 200 °C; spray voltage, 3.6 kV for positive and negative modes; capillary temperature, 325 °C; and funnel RF level, 65. Samples were analyzed by full MS with polarity switching. Full MS scans were acquired at 60,000 resolution with 2 microscans and a scan range of 72-1080 m/z, automatic gain control (AGC) target of 5e6, and maximum injection time (IT) of 200 ms.
Ion Mode:UNSPECIFIED