This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001719. The data can be accessed directly via it's Project DOI: 10.21228/M8HF01 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002758
Study TitleMetabolic responses of normal rat kidneys to a high salt intake (Plasma)
Study TypeTime-course metabolomics experiment
Study SummaryIn this study, novel methods were developed which allowed continuous (24/7) measurement of arterial blood pressure and renal blood flow in freely moving rats and the intermittent collection of arterial and renal venous blood to estimate kidney metabolic fluxes of O2 and metabolites. Specifically, the study determined the effects of a high salt (HS; 4.0% NaCl) diet upon whole kidney O2 consumption and arterial and renal venous plasma metabolomic profiles of normal Sprague-Dawley rats. A separate group of rats was studied to determine changes in the cortex and outer medulla tissue metabolomic profiles before and following the switch from a 0.4% to 4.0% NaCl diet.
Institute
Medical College of Wisconsin
DepartmentPhysiology
LaboratoryDr. Allen W. Cowley
Last NameCowley
First NameAllen
Address8701 W. Watertown Plank Rd, Milwaukee, WI 53226
Emailcowley@mcw.edu
Phone4149558277
Submit Date2023-06-26
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2023-07-02
Release Version1
Allen Cowley Allen Cowley
https://dx.doi.org/10.21228/M8HF01
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004475 AN004476 AN004477 AN004478
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Agilent InfinityLab Poroshell 120 EC-C18 (2.1 x 50 mm; 2.7-Micron) Agilent InfinityLab Poroshell 120 HILIC-Z (2.1 x 50 mm; 2.7 micron; #689775-924) Agilent InfinityLab Poroshell 120 HILIC-Z (2.1 x 50 mm; 2.7 micron; #689775-924) Agilent InfiinityLab Poroshell 120 HILIC-Z (2.1 x 50 mm; 2.7 micron; #689775-924)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Area Area Area Area

MS:

MS ID:MS004222
Analysis ID:AN004475
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:C18 positive plasma data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow.
Ion Mode:POSITIVE
  
MS ID:MS004223
Analysis ID:AN004476
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:C18 negative plasma data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow.
Ion Mode:NEGATIVE
  
MS ID:MS004224
Analysis ID:AN004477
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:HILIC positive plasma data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow.
Ion Mode:POSITIVE
  
MS ID:MS004225
Analysis ID:AN004478
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:HILIC negative plasma data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow.