Summary of Study ST003074

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001914. The data can be accessed directly via it's Project DOI: 10.21228/M89T5V This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003074
Study TitleSpectral information for 3,5,3’-L-triiodothyronine (T3) and 3,5,3’5’-L-tetraiodothyronine (T4) from synthetic standards
Study SummaryWe utilized synthetic standards for 3,5,3’-L-triiodothyronine (T3) and 3,5,3’5’-L-tetraiodothyronine (T4) to obtain high-quality MS2-level information that would aid compound identification from biological matrixes
Institute
Boston Childrens Hospital
DepartmentPatholody
LaboratoryKanarek Lab
Last NamePetrova
First NameBoryana
Address300 Longwood Av
Emailboryana.petrova@childrens.harvard.edu
Phone6173557433
Submit Date2024-01-11
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-02-14
Release Version1
Boryana Petrova Boryana Petrova
https://dx.doi.org/10.21228/M89T5V
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005032
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Merck Supelco Ascentis Express C18 (150 x 2.1mm,2.7um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units NA

MS:

MS ID:MS004771
Analysis ID:AN005032
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS data acquisition was performed using a Q Exactive Orbitrap benchtop orbitrap mass spectrometer equipped with an Ion Max source and a HESI II probe (Thermo Fisher Scientific, San Jose, CA, USA)in positive ionization mode and a PRM acquisition with the resolution set at 17,500, the AGC target at 2 × 10^5, and the maximum injection time (Max IT) at 40 msec. Collision energies were set at 20,40,60 and 80 NCE. Inclusion list was 651.7973 m/z for T3 and 777.6940 m/z for T4. HESI conditions were as follows: sheath gas flow rate: 40 units; Aug gas flow rate: 10 units; sweet gas flow rate: 0; spray voltage: 3.5 kV (pos), 2.8 kV (neg); capillary temperature: 380 °C; S-lens RF: 60; Aux gas heater temperature: 420 °C. MS spectra were consolidated using the mzVault software, automatically thresholded for noise and recalibrated for mass error.
Ion Mode:POSITIVE