Summary of Study ST003077
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001916. The data can be accessed directly via it's Project DOI: 10.21228/M82B0Z This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST003077 |
Study Title | Data-dependent and -independent acquisition lipidomics analysis reveals the tissue-dependent effect of metformin on lipid metabolism (Adipose tissue measurements) |
Study Summary | Lipidomics analysis of 6 mouse tissues and plasma using MS/MS combining BRI-DIA and DDA allowed a systemic evaluation of lipidomic changes induced by metformin in different tissues. We observed that 1) the degrees of lipidomic changes induced by metformin treatment overly correlated with tissue concentrations of metformin; 2) the impact on lysophosphorylcholine and cardiolipins was positively correlated with tissue concentrations of metformin, while neutral lipids such as triglycerides did not correlate with the corresponding tissue metformin concentrations. |
Institute | North Carolina State University |
Last Name | Liu |
First Name | Xiaojing |
Address | 128 Polk Hall, 120 W Broughton Dr. |
xliu68@ncsu.edu | |
Phone | 919.515.4387 |
Submit Date | 2024-02-06 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2024-03-01 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005035 |
---|---|
Analysis type | MS |
Chromatography type | Reversed phase |
Chromatography system | Thermo Vanquish |
Column | Xbridge BEH C18 column (100 × 2.1 mm, 2.5 um) |
MS Type | ESI |
MS instrument type | Orbitrap |
MS instrument name | Thermo Orbitrap Exploris 480 |
Ion Mode | UNSPECIFIED |
Units | arbitrary unit |
MS:
MS ID: | MS004774 |
Analysis ID: | AN005035 |
Instrument Name: | Thermo Orbitrap Exploris 480 |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The relevant parameters of Orbitrap Exploris 480 were as listed: vaporizer temperature, 350 °C; ion transfer tube temperature, 300 °C; sheath gas, 35; auxiliary gas, 7; sweep gas, 1; spray voltage, 3.5 kV for positive mode and 2.5 kV for negative mode; RF-lens (%), 45. The resolution was set at 120,000 (at m/z 200). The scan range was 200 to 1600 (m/z). Automatic maximum injection time (max IT) and automatic gain control (AGC) were used. MS/MS scan was acquired using Hybrid mode (BRI-DIA followed by DDA) with the inclusion list containing precursor ions in positive and negative ion mode (described in the Supplementary table 1 of our prior publication PMID: 35842862). The MS/MS condition for positive or negative ion mode was set as follows: precursor isolation window was set at 1 (m/z) for all three methods, HCD collision energy was set at 25%, orbitrap resolution of full scan and MS/MS scan was set at 60,000 and 15,000, respectively. Intensity threshold for DDA and DIA MS/MS scan was set at 10,000. LC-MS peak extraction and integration were performed using MS-DIAL with default settings. |
Ion Mode: | UNSPECIFIED |