Summary of Study ST003094
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001923. The data can be accessed directly via it's Project DOI: 10.21228/M85149 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST003094 |
Study Title | Lactiplantibacillus plantarum intervention on serum untargeted metabolome of gestational fecal microbiome transplant germ-free mice |
Study Summary | The study aims to investigate whether administration of probiotic L. plantarum could influence profiling of serum untargeted metabolome of germ-free mice. Results showed that there were 23 metabolites significantly different in intervention group. |
Institute | Beijing Sanyuan Foods Co. Ltd |
Last Name | Lijun |
First Name | Chen |
Address | 8th yingchang street, yinghai distric |
chenlijun@sanyuan.com.cn | |
Phone | 01056306594 |
Submit Date | 2024-02-17 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2024-03-08 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005064 | AN005065 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | LC | LC |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um) | Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Orbitrap Exploris 120 | Thermo Orbitrap Exploris 120 |
Ion Mode | POSITIVE | NEGATIVE |
Units | m/z values | m/z values |
MS:
MS ID: | MS004802 |
Analysis ID: | AN005064 |
Instrument Name: | Thermo Orbitrap Exploris 120 |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | MS1 range was 100-1000 m/z, and the number of data-dependent scans per cycle was 4; MS/MS resolving power was 15000 FWHM, normalized collision energy was 30%, and dynamic exclusion time was automatic. The raw data were firstly converted to mzXML format by MSConvert in the ProteoWizard software package (v3.0.8789) (Adusumilli et al., 2017) and processed using XCMS (Domingo-Almenara et al., 2020) for feature detection, retention time correction and alignment. |
Ion Mode: | POSITIVE |
MS ID: | MS004803 |
Analysis ID: | AN005065 |
Instrument Name: | Thermo Orbitrap Exploris 120 |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | MS1 range was 100-1000 m/z, and the number of data-dependent scans per cycle was 4; MS/MS resolving power was 15000 FWHM, normalized collision energy was 30%, and dynamic exclusion time was automatic. The raw data were firstly converted to mzXML format by MSConvert in the ProteoWizard software package (v3.0.8789) (Adusumilli et al., 2017) and processed using XCMS (Domingo-Almenara et al., 2020) for feature detection, retention time correction and alignment. |
Ion Mode: | NEGATIVE |